BACKGROUND: Chronic haemodialysis (HD) may relieve some medical problems of terminal uraemia, but the life expectancy of patients is still significantly shortened, and there is a greatly increased morbidity. This includes pulmonary morbidity and chronic central nervous system (CNS) abnormalities. Previous studies have shown that a considerable amount of air microbubbles emanate within the blood lines of the dialysis device and pass the air detector without sounding an alarm. The aim of this study was to investigate whether microemboli can pass to the patient and whether they could be detected in the carotid artery. METHODS: A total of 54 patients on chronic HD (16 with central dialysis catheter) were investigated with an ultrasound detector (Hatteland, Røyken, Norway) for the presence of microemboli at the arteriovenous (AV) fistula/graft and at the common carotid artery before and during HD. Measurements were taken for 2 and 5 min, respectively. Non-parametric paired statistics were used (Wilcoxon). RESULTS: The median number (range) and mean +/- SD of microembolic signals detected at the AV access site before commencing dialysis and during HD were 0 (0-3) and 0.2+/- 0.5 versus 4 (0-85) and 13.5 +/- 20 (P = 0.000); at the carotid artery, 1 (0-14) and 1.7 +/- 2.9 versus 2 (0-36) and 3.5 +/- 5.8 (P = 0.008). CONCLUSIONS: The infused and returning fluid from HD devices contains air microbubbles that enter the patient without triggering any alarms. These small emboli pass the lung and may cause ischaemic lesions in organs supported by the arterial circuit, such as the brain.
BACKGROUND: Chronic haemodialysis (HD) may relieve some medical problems of terminal uraemia, but the life expectancy of patients is still significantly shortened, and there is a greatly increased morbidity. This includes pulmonary morbidity and chronic central nervous system (CNS) abnormalities. Previous studies have shown that a considerable amount of air microbubbles emanate within the blood lines of the dialysis device and pass the air detector without sounding an alarm. The aim of this study was to investigate whether microemboli can pass to the patient and whether they could be detected in the carotid artery. METHODS: A total of 54 patients on chronic HD (16 with central dialysis catheter) were investigated with an ultrasound detector (Hatteland, Røyken, Norway) for the presence of microemboli at the arteriovenous (AV) fistula/graft and at the common carotid artery before and during HD. Measurements were taken for 2 and 5 min, respectively. Non-parametric paired statistics were used (Wilcoxon). RESULTS: The median number (range) and mean +/- SD of microembolic signals detected at the AV access site before commencing dialysis and during HD were 0 (0-3) and 0.2+/- 0.5 versus 4 (0-85) and 13.5 +/- 20 (P = 0.000); at the carotid artery, 1 (0-14) and 1.7 +/- 2.9 versus 2 (0-36) and 3.5 +/- 5.8 (P = 0.008). CONCLUSIONS: The infused and returning fluid from HD devices contains air microbubbles that enter the patient without triggering any alarms. These small emboli pass the lung and may cause ischaemic lesions in organs supported by the arterial circuit, such as the brain.
Authors: Wondwossen G Tekle; Cheryl D Adkinson; Saqib A Chaudhry; Vikram Jadhav; Ameer E Hassan; Gustavo J Rodriguez; Adnan I Qureshi Journal: Neurocrit Care Date: 2013-04 Impact factor: 3.210
Authors: Gabor Erdoes; Dominik E Uehlinger; Beatrice Kobel; Monika P Stucki; Roland Wiest; Frank Stueber; Niklaus Fankhauser; Stephan M Jakob; Joerg C Schefold Journal: Trials Date: 2018-03-21 Impact factor: 2.279
Authors: Junko Goto; Ulf Forsberg; Per Jonsson; Kenichi Matsuda; Bo Nilsson; Kristina Nilsson Ekdahl; Michael Y Henein; Bernd G Stegmayr Journal: Int J Artif Organs Date: 2020-12-18 Impact factor: 1.595