Literature DB >> 20304349

Wire-guided catheter exchange after failed direct laryngoscopy in critically ill adults.

Aaron M Joffe1, George Arndt, Karl Willmann.   

Abstract

STUDY
OBJECTIVE: To describe a technique for tracheal intubation after failed direct laryngoscopy using a Laryngeal Mask Airway (LMA) to secure the airway and to establish ventilation, and as a conduit for fiberoptic intubation utilizing a pre-packaged, convenient, and commercially available wire-guided catheter exchange kit.
DESIGN: Retrospective case series.
SETTING: University hospital. MEASUREMENTS: The cases of 5 critically ill adult patients who required intubation for respiratory failure, and in whom direct laryngoscopy was unsuccessful and unanticipated, were reviewed. Difficult intubation was defined as > or = two attempts by direct laryngoscopy and use of an airway adjunct/alternate airway device, or > or = three attempts by direct laryngoscopy. Occurrence of hypotension, hypoxemia, and the time required to accomplish the intubation were recorded. MAIN
RESULTS: Patients' tracheas were intubated in the emergency department (n = 2), the intensive care unit (n = 2), and the radiology department (n = 1). An Eschmann endotracheal tube (ETT) introducer was used in 4 of the 5 patients, and a GlideScope was used in the fifth patient. After failed direct laryngoscopy, an LMA Classic was inserted to gain an airway, after which a fiberoptic bronchoscope and wire-guided catheter exchange set was used to change the LMA to a conventional ETT. Ventilation was maintained via the LMA with an attached bronchoscope adapter throughout the procedure.
CONCLUSIONS: In all 5 patients, the trachea was successfully intubated within three minutes on the first attempt, using a wire-guided exchange, without hypoxemia or hypotension. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20304349     DOI: 10.1016/j.jclinane.2009.02.017

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  2 in total

1.  Wire-guided (Seldinger technique) intubation through a face mask in urgent, difficult and grossly distorted airways.

Authors:  Jake M Heier; Kristopher M Schroeder; Richard E Galgon; George A Arndt
Journal:  Saudi J Anaesth       Date:  2012-07

2.  Successful wire-guided fiberoptic nasotracheal intubation in a patient with hemifacial microsomia - A case report.

Authors:  Seon Ju Kim; Haeyeon Lee; Seung Yeon Choi; Bon-Nyeo Koo
Journal:  Anesth Pain Med (Seoul)       Date:  2020-01-31
  2 in total