Literature DB >> 20303291

Optimization of glenoid fixation in reverse shoulder arthroplasty using 3-dimensional modeling.

Levi G Sutton1, Frederick W Werner, Alyssa K Jones, Christopher A Close, Vipul N Nanavati.   

Abstract

BACKGROUND: Reverse shoulder fixation complications may be related to how much glenoid bone is removed and how the fixation screws are located in the glenoid. The purpose of this study was to determine how much bone volume and surface area are lost with incremental reaming and to evaluate screw fixation.
METHODS: A contemporary reverse shoulder implant was virtually implanted into models of 6 different shoulders following initial and then after additional incremental reaming was performed. Changes in the glenoid bone surface area and volume available for fixation were statistically evaluated using repeated measures ANOVAs.
RESULTS: The total bone volume, the amount of reamed glenoid surface area available for an implant baseplate, and the actual amount of the glenoid in contact with a baseplate decreased with increasing amounts of reaming. With 5 mm of reaming, the total volume decreased by 2810 mm(3), the reamed glenoid surface area decreased by 28%, and the amount of the glenoid in contact with the baseplate decreased by 27%. The amount of engagement of anterior and posterior screws was much less than that of the superior and inferior screws.
CONCLUSION: Careful reaming of the glenoid surface is critical, because as little as 1 extra millimeter of bone removal decreases the amount of bone available for implant fixation. After reaming there may not be enough bone to accommodate anterior and posterior screws with the design used in this study. 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20303291     DOI: 10.1016/j.jse.2009.12.003

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  5 in total

1.  Outcomes after shoulder arthroplasty revision with glenoid reconstruction and bone grafting.

Authors:  Thomas Hoffelner; Philipp Moroder; Alexander Auffarth; Mark Tauber; Herbert Resch
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

2.  Reverse total shoulder arthroplasty: research models.

Authors:  Stefano Petrillo; Umile Giuseppe Longo; Lawrence V Gulotta; Alessandra Berton; Andreas Kontaxis; Timothy Wright; Vincenzo Denaro
Journal:  Joints       Date:  2017-02-07

3.  Glenoid baseplate fixation using hybrid configurations of locked and unlocked peripheral screws.

Authors:  Nathan T Formaini; Nathan G Everding; Jonathan C Levy; Brandon G Santoni; Aniruddh N Nayak; Cooper Wilson
Journal:  J Orthop Traumatol       Date:  2017-01-11

4.  Reverse Total Shoulder Arthroplasty Baseplate Stability in Superior Bone Loss With Augmented Implant.

Authors:  Elise J Martin; Thomas R Duquin; Mark T Ehrensberger
Journal:  J Shoulder Elb Arthroplast       Date:  2021-06-13

5.  CT scan evaluation of glenoid bone and pectoralis major tendon: interest in shoulder prosthesis.

Authors:  Laurent Obert; Christelle Peyron; Etienne Boyer; Gauthier Menu; François Loisel; Sébastien Aubry
Journal:  SICOT J       Date:  2016-10-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.