Literature DB >> 2030031

Dynamic hip screws that fail.

A P Thomas1.   

Abstract

A series of 87 trochanteric fractures of the femur treated by dynamic hip screw, was reviewed. The relationship between the position of the fracture fragments and the position of the hip screw in the femoral head was investigated. Hip screws inserted into some parts of the femoral head were more likely to cut out than others. Some fractures were undisplaced or had been perfectly reduced. A lateral radiograph of some of the others showed that the femoral head and neck were aligned with the shaft. Only among these fractures was the number of good screw placements as great as among those that were undisplaced or perfectly reduced.

Entities:  

Mesh:

Year:  1991        PMID: 2030031     DOI: 10.1016/0020-1383(91)90161-7

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  8 in total

1.  Is helical blade nailing superior to locked minimally invasive plating in unstable pertrochanteric fractures?

Authors:  Matthias Knobe; Wolf Drescher; Nicole Heussen; Richard Martin Sellei; Hans-Christoph Pape
Journal:  Clin Orthop Relat Res       Date:  2012-02-07       Impact factor: 4.176

2.  A new technique for lag screw placement in the dynamic hip screw fixation of intertrochanteric fractures: decreasing radiation time dramatically.

Authors:  Wei-Chao Sheng; Jia-Zhen Li; Sheng-Hua Chen; Shi-Zhen Zhong
Journal:  Int Orthop       Date:  2008-02-12       Impact factor: 3.075

3.  Femoral shaft medialisation and neck-shaft angle in unstable pertrochanteric femoral fractures.

Authors:  J Pajarinen; J Lindahl; V Savolainen; O Michelsson; E Hirvensalo
Journal:  Int Orthop       Date:  2004-09-10       Impact factor: 3.075

4.  Primary hemiarthroplasty for unstable osteoporotic intertrochanteric fractures in the elderly: A retrospective case series.

Authors:  Kh Sancheti; Pk Sancheti; Ak Shyam; S Patil; Q Dhariwal; R Joshi
Journal:  Indian J Orthop       Date:  2010-10       Impact factor: 1.251

5.  A biomechanical study comparing helical blade with screw design for sliding hip fixations of unstable intertrochanteric fractures.

Authors:  Qiang Luo; Grace Yuen; Tak-Wing Lau; Kelvin Yeung; Frankie Leung
Journal:  ScientificWorldJournal       Date:  2013-02-20

6.  A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study.

Authors:  Jin-Ho Hwang; Anant Kumar Garg; Jong-Keon Oh; Chang-Wug Oh; Sung-Jae Lee; Cho Myung-Rae; Min-Keun Kim; Hyun Kim
Journal:  Indian J Orthop       Date:  2012-11       Impact factor: 1.251

7.  A cascade of preventable complications following a missed femoral neck fracture after antegrade femoral nailing.

Authors:  Lucas S McDonald; Frances Tepolt; Dominic Leonardelli; E Mark Hammerberg; Philip F Stahel
Journal:  Patient Saf Surg       Date:  2013-05-23

8.  A review of tip apex distance in dynamic hip screw fixation of osteoporotic hip fractures.

Authors:  Imran Haruna Abdulkareem
Journal:  Niger Med J       Date:  2012-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.