Literature DB >> 20299974

Straylight measurements in contact lens wear.

Ivanka J E van der Meulen1, Leonore A Engelbrecht, Johannes M J van Vliet, Ruth Lapid-Gortzak, Carla P Nieuwendaal, Maarten P Mourits, Reinier O Schlingemann, Thomas J T P van den Berg.   

Abstract

PURPOSE: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints.
METHODS: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens removal in 30 rigid contact lens wearers and 30 soft contact lens wearers. Semi-quantitative (0-4) slit-lamp grading of anterior segment changes using Efron grading scales and contact lens characteristics were performed. Subjects answered a straylight questionnaire.
RESULTS: Soft contact lens wearers had a mean straylight of logarithmic value of the straylight parameter [log(s)] = 0.934 during contact lens wear and after contact lens removal [comparable to log(s) = 0.938 of age-matched normal eyes]. Rigid contact lens wearers had a mean straylight during contact lens wear of log(s) = 1.167. After contact lens removal, log(s) significantly decreased to 0.997 (P < 0.01). Straylight values with rigid contact lenses were strongly increased (P < 0.001) compared with age-matched normal eyes; after contact lens removal, these values decreased but remained elevated. Straylight in rigid contact lens wearers correlated with the amount of deposits on the contact lens (P < 0.01) but not with other variables of the contact lens score. The questionnaire showed more straylight complaints in rigid contact lens wearers than in soft contact lens wearers (P < 0.01).
CONCLUSIONS: Rigid contact lens wear leads to increased straylight during contact lens wear and after contact lens removal. This may be because of subclinical effects of contact lens wear on the cornea and is not seen in soft contact lens wearers.

Entities:  

Mesh:

Year:  2010        PMID: 20299974     DOI: 10.1097/ICO.0b013e3181c11e29

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  6 in total

1.  Analysis of optical side-effects of fs-laser therapy in human presbyopic lens simulated with modified contact lenses.

Authors:  Monika Peter; Robert Kammel; Roland Ackermann; Stefan Schramm; Bernd-Ulrich Seifert; Katharina Frey; Marcus Blum; Stefan Nolte; Kathleen S Kunert
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-29       Impact factor: 3.117

2.  Fluctuation in straylight measurements during the visual recovery phase after small incision lenticule extraction.

Authors:  Kelvin H Wan; Rachel W Y Tsui; Tommy C Y Chan
Journal:  Eye (Lond)       Date:  2019-08-09       Impact factor: 3.775

3.  Straylight As The Result Of Refractive Correction.

Authors:  Zoraida S Gaurisankar; Gwyneth A van Rijn; Gregorius Pm Luyten; Thomas Jtp van den Berg
Journal:  Clin Ophthalmol       Date:  2019-11-12

4.  Influence of macular pigment optical density spatial distribution on intraocular scatter.

Authors:  Christopher M Putnam; Pauline J Bland; Carl J Bassi
Journal:  J Optom       Date:  2015-11-24

5.  Changes in corneal densitometry after long-term orthokeratology for myopia and short-term discontinuation.

Authors:  Lianghui Zhao; Lili Jing; Jie Li; Xianli Du
Journal:  PLoS One       Date:  2022-02-04       Impact factor: 3.240

6.  Contrast sensitivity and higher-order aberrations in Keratoconus subjects.

Authors:  Einat Shneor; David P Piñero; Ravid Doron
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.