Literature DB >> 20299025

Separation of intact proteins on porous layer open tubular (PLOT) columns.

Magnus Rogeberg1, Steven Ray Wilson, Tyge Greibrokk, Elsa Lundanes.   

Abstract

Porous layer open tubular (PLOT) polystyrene divinylbenzene columns have been used for separating intact proteins with gradient elution. The 10 microm I.D. x 3 m columns were easily coupled to standard liquid chromatography-mass spectrometry (LC-MS) instrumentation with commercially available fittings. Standard proteins separated on PLOT columns appeared as narrow and symmetrical peaks with good resolution. Average peak width increased linearly with gradient time (tG) from 0.14 to 0.33 min (tG 20 and 120 min, respectively) using a 3 m column. With shorter columns, peak widths were larger and increased more steeply with gradient time. Theoretical peak capacity (nc) increased with column length (tested up to 3 m). The nc increased with tG until a plateau was reached. The highest peak capacity achieved (nc=185) was obtained with a 3 m column, where a plateau was reached with tG 90 min. The within- and between column retention time repeatabilities were below 0.6% and below 2.5% (relative standard deviation, RSD), respectively. The carry-over following injection of 0.5 ng per protein was less than 1.1%. The retention time dependence on column temperature was investigated in the range 20-50 degrees C. Proteins in a skimmed milk sample were separated using the method. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20299025     DOI: 10.1016/j.chroma.2010.02.025

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Microproteomic analysis of 10,000 laser captured microdissected breast tumor cells using short-range sodium dodecyl sulfate-polyacrylamide gel electrophoresis and porous layer open tubular liquid chromatography tandem mass spectrometry.

Authors:  Dipak Thakur; Tomas Rejtar; Dongdong Wang; Jonathan Bones; Sangwon Cha; Buffie Clodfelder-Miller; Elizabeth Richardson; Shemeica Binns; Sonika Dahiya; Dennis Sgroi; Barry L Karger
Journal:  J Chromatogr A       Date:  2011-09-14       Impact factor: 4.759

2.  Integrated enzyme reactor and high resolving chromatography in "sub-chip" dimensions for sensitive protein mass spectrometry.

Authors:  Hanne Kolsrud Hustoft; Ole Kristian Brandtzaeg; Magnus Rogeberg; Dorna Misaghian; Silje Bøen Torsetnes; Tyge Greibrokk; Léon Reubsaet; Steven Ray Wilson; Elsa Lundanes
Journal:  Sci Rep       Date:  2013-12-16       Impact factor: 4.379

Review 3.  Different Stationary Phase Selectivities and Morphologies for Intact Protein Separations.

Authors:  A Astefanei; I Dapic; M Camenzuli
Journal:  Chromatographia       Date:  2016-09-23       Impact factor: 2.044

4.  Open tubular lab-on-column/mass spectrometry for targeted proteomics of nanogram sample amounts.

Authors:  Hanne Kolsrud Hustoft; Tore Vehus; Ole Kristian Brandtzaeg; Stefan Krauss; Tyge Greibrokk; Steven Ray Wilson; Elsa Lundanes
Journal:  PLoS One       Date:  2014-09-15       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.