Intensity modulated radiation therapy (IMRT) surface dose measurements using a PTW advanced Markus chamber.

F Q Chen1, R Gupta, P Metcalfe.   

Abstract

A new PTW advanced Markus ionization chamber has been implemented in IMRT fields, to measure surface dose at ICRU and ICRP reference depth of 0.07 mm [ICRU Report 39, Determination of dose equivalents resulting from external radiation sources, 1985; ICRP Publication 60, 1990 recommendations of the International Commission on Radiological Protection, 1991]. This chamber has a small radius with a revised guard ring design, therefore less prone to surface over-response effects. The over response correction for advanced Markus chamber is 3.3%, which is significantly smaller than 10.1% which was the original Markus chamber over response. After over response correction, the surface dose can be accurately measured by either data extrapolation or by adding one layer of plastic sheet protector to the top of Markus chamber. The surface dose measurements for small fields, e.g 3 x 3 cm, the polarity effect of advanced Markus chamber is 12%, which is significantly higher than the 5% polarity effect of the original Markus. For a 12 x 12 cm field size, surface dose (at 0.07 mm) measured by advanced Markus chamber is 19.8% for open field and 19.2% for an unmodulated step-and-shoot IMRT field. The variation in surface dose due to intensity modulated IMRT fields has also been investigated. For an intensity modulated, step-wedge IMRT field, surface dose varies from 15.7 + or - 1% for the highest intensity segment to 26.9 + or - 1% for the lowest intensity segment. The results of chamber measurements have been compared against EBT type GAFCHROMIC film results.

Entities:  

Mesh:

Year:  2010        PMID: 20237890     DOI: 10.1007/s13246-010-0004-x

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  4 in total

1.  Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantoms.

Authors:  Rongxiao Zhang; Colleen J Fox; Adam K Glaser; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2013-07-24       Impact factor: 3.609

2.  On the Use of Optically Stimulated Luminescent Dosimeter for Surface Dose Measurement during Radiotherapy.

Authors:  Fasihah Hanum Yusof; Ngie Min Ung; Jeannie Hsiu Ding Wong; Wei Loong Jong; Vannyat Ath; Vincent Chee Ee Phua; Siew Ping Heng; Kwan Hoong Ng
Journal:  PLoS One       Date:  2015-06-08       Impact factor: 3.240

3.  An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements.

Authors:  Lukkana Apipunyasopon; Somyot Srisatit; Nakorn Phaisangittisakul
Journal:  J Radiat Res       Date:  2012-10-26       Impact factor: 2.724

4.  Beam perturbation characteristics of a 2D transmission silicon diode array, Magic Plate.

Authors:  Ziyad A Alrowaili; Michael L F Lerch; Marco Petasecca; Martin G Carolan; Peter E Metcalfe; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.