Literature DB >> 20237180

Influence of the elasticity module of synthetic and natural polymeric tissue substitutes on the mobility of the diaphragm and healing process in a rabbit model.

G Böhm1, M Binnebösel, E Krähling, V Schumpelick, G Steinau, S Stanzel, M Anurov, S Titkova, A Ottinger, M Speer.   

Abstract

Mesh implants are frequently used in congenital diaphragmatic hernia. This experimental study aimed to examine the influence of different materials on the diaphragmatic movement over time as well as their mechanical qualities after 4 months. Ultrapro®, Surgisis®, and Proceed® were implanted onto a diaphragmatic defect in growing rabbits. Diaphragmatic mobility was determined at three time points. At 4 months, defect shrinkage and mechanical properties were measured. The break strength decreased for Ultrapro® and Surgisis®, but did not change relevantly for Proceed®. Ultrapro® (32.46 N/cm) and Proceed® (31.75 N/cm) showed a four-fold higher resistance to tearing than Surgisis® (8.31 N/cm). The elasticity of Ultrapro® showed no significant difference compared to Surgisis® (p = 0.75). Proceed®, on the other hand, was more than twice as elastic as Ultrapro® or Surgisis® (p = 0.015). Ultrapro® had a higher spring rate (6.48 N/mm) compared to Surgisis® (3.82 N/mm) or Proceed® (5.23 N/mm). Observing the standardized movement rates of the diaphragm for each mesh group over time the only statistical differences were seen for the Proceed® group. On account of its material qualities Ultrapro® was found to be the most suitable mesh material for demanding locations in our model.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20237180     DOI: 10.1177/0885328209360423

Source DB:  PubMed          Journal:  J Biomater Appl        ISSN: 0885-3282            Impact factor:   2.646


  3 in total

Review 1.  A review of patch options in the repair of congenital diaphragm defects.

Authors:  Alessandra C Gasior; Shawn D St Peter
Journal:  Pediatr Surg Int       Date:  2012-04       Impact factor: 1.827

2.  A comparison of two types of preperitoneal mesh prostheses in stoma surgery: application to an animal model.

Authors:  G Tadeo; J Picazo; C Moreno; R Cuesta
Journal:  Hernia       Date:  2012-08-08       Impact factor: 4.739

3.  A growing animal model for neonatal repair of large diaphragmatic defects to evaluate patch function and outcome.

Authors:  Mary Patrice Eastwood; Luc Joyeux; Savitree Pranpanus; Johannes Van der Merwe; Eric Verbeken; Stephanie De Vleeschauwer; Ghislaine Gayan-Ramirez; Jan Deprest
Journal:  PLoS One       Date:  2017-03-30       Impact factor: 3.240