Literature DB >> 2023715

Quantitative scoring methods for D15 panel tests in the diagnosis of congenital color vision deficiencies.

D A Atchison1, K J Bowman, A J Vingrys.   

Abstract

Farnsworth's standard D15 and L'Anthony's desaturated D15 panel tests were administered to 99 congenital red-green color defective subjects. The results were analyzed in three ways: (1) by summing the color differences between adjacent caps according to Bowman, (2) by averaging color difference vectors (CDV) according to Vingrys and King-Smith, and (3) by visually inspecting and counting the crossings. The Bowman measure was highly correlated with one of the CDV measures but provides less information regarding a cap arrangement. The desaturated D15 test can be expected to misclassify 5% of dichromats by type (protan/deutan) compared to a type misclassification rate of less than 0.1% for the D15 panel test. The correct diagnostic rates for type were 45% for the standard D15 test and 58% for the desaturated D15 test. However, the improvement in correct diagnostic rate for the latter test was accompanied by an increase in the misdiagnostic rate from 2 to 10%. The main value of the desaturated D15 test in congenital color vision diagnosis would seem to be in providing classification of those subjects who pass the standard D15 test. Quantitative scoring of the tests provides a good estimate of severity of defect. Visual inspection provides a similar diagnostic rate to CDV analysis, but has a lower type misdiagnostic rate at the desaturated D15 test and is more likely to be correct when the two methods disagree. We suggest that quantitative scoring techniques are of limited benefit for the clinical diagnosis of congenital color vision defects but that they are of use in clinical trials or for the monitoring of changes in color vision over time.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 2023715     DOI: 10.1097/00006324-199101000-00007

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

1.  The artificial silicon retina in retinitis pigmentosa patients (an American Ophthalmological Association thesis).

Authors:  Alan Y Chow; Ava K Bittner; Machelle T Pardue
Journal:  Trans Am Ophthalmol Soc       Date:  2010-12

2.  +Psychometric evaluation of the MacDQoL individualised measure of the impact of macular degeneration on quality of life.

Authors:  Jan Mitchell; James S Wolffsohn; Alison Woodcock; Stephen J Anderson; Carolyn V McMillan; Timothy Ffytche; Martin Rubinstein; Winfried Amoaku; Clare Bradley
Journal:  Health Qual Life Outcomes       Date:  2005-04-14       Impact factor: 3.186

3.  A modified pseudoisochromatic ishihara colour vision test based on eastern arabic numerals.

Authors:  Fatemeh Heidary; Reza Gharebaghi
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2013

4.  Evaluation of clinical validity of the Rabin cone contrast test in normal phakic or pseudophakic eyes and severely dichromatic eyes.

Authors:  Masato Fujikawa; Sanae Muraki; Yuichi Niwa; Masahito Ohji
Journal:  Acta Ophthalmol       Date:  2017-05-29       Impact factor: 3.761

5.  Development of a Spatio-temporal Contrast Sensitivity Test for Clinical Use.

Authors:  Marcelo Fernandes Costa; Leonardo Dutra Henriques; Otávio Côrrea Pinho
Journal:  J Ophthalmic Vis Res       Date:  2022-01-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.