Literature DB >> 20233807

Absence of prosthesis-patient mismatch with the new generation of Edwards stented aortic bioprosthesis.

Thomas R Wyss1, Marc Bigler, Mario Stalder, Lars Englberger, Thierry Aymard, Alexander Kadner, Thierry P Carrel.   

Abstract

Prosthesis-patient mismatch (PPM) remains a controversial issue with the most recent stented biological valves. We analyzed the incidence of PPM after implantation of the Carpentier-Edwards Perimount Magna Ease aortic valve (PMEAV) bioprosthesis and assessed the early clinical outcome. Two hundred and seventy consecutive patients who received a PMEAV bioprosthesis between January 2007 and July 2008 were analyzed. Pre-, peri- and postoperative data were assessed and echocardiographic as well as clinical follow-up was performed. Mean age was 72+/-9 years, 168 (62.2%) were males. Fifty-seven patients (21.1%) were below 65 years of age. Absence of PPM, corresponding to an indexed effective orifice area >0.85 cm(2)/m(2), was 99.5%. Observed in-hospital mortality was 2.2% (six patients), with a predicted mortality according to the additive EuroSCORE of 7.6+/-3.1%. At echocardiographic assessment after a mean follow-up period of 150+/-91 days, mean transvalvular gradient was 11.8+/-4.8 mmHg (all valve sizes). No paravalvular leakage was seen. Nine patients died during follow-up. The Carpentier-Edwards PMEAV bioprosthesis shows excellent hemodynamic performance. This valve can be implanted in all sizes with an incidence of severe PPM below 0.5%.

Entities:  

Mesh:

Year:  2010        PMID: 20233807     DOI: 10.1510/icvts.2009.224915

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  8 in total

1.  Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.

Authors:  Naritomo Nishioka; Akira Yamada; Kosuke Ujihira; Yutaka Iba; Ryushi Maruyama; Eiichiro Hatta; Yoshihiko Kurimoto; Katsuhiko Nakanishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-08-04

2.  Optimizations of stent and tissue leaflets in a new surgical bovine pericardial valve.

Authors:  Jinmiao Chen; Jun Yang; Li Zhang; Wenrui Ma; Shuyang Lu; Chunsheng Wang; Tao Hong
Journal:  J Thorac Dis       Date:  2019-11       Impact factor: 2.895

3.  Serial echocardiographic evaluation of the Perimount Magna Ease prosthesis.

Authors:  Benedikt Mayr; Melchior Burri; Keti Vitanova; Anatol Prinzing; Gertrud Goppel; Markus Krane; Rüdiger Lange; Ralf Günzinger
Journal:  J Thorac Dis       Date:  2021-07       Impact factor: 2.895

Review 4.  Current status and future perspectives of prosthetic valve selection for aortic valve replacement.

Authors:  Hiroshi Furukawa; Kazuo Tanemoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-05-31

5.  Early Doppler-echocardiography evaluation of Carpentier-Edwards Standard and Carpentier-Edwards Magna aortic prosthetic valve: comparison of hemodynamic performance.

Authors:  Giovanni Minardi; Giovanni Pulignano; Donatella Del Sindaco; Martina Sordi; Herribert Pavaci; Amedeo Pergolini; Giordano Zampi; Francesca Moschella Orsini; Carlo Gaudio; Francesco Musumeci
Journal:  Cardiovasc Ultrasound       Date:  2011-11-24       Impact factor: 2.062

6.  Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve.

Authors:  Jinmiao Chen; Minzhi Lv; Yuntao Lu; Jiahui Fu; Yingqiang Guo; Liang Tao; Xinmin Zhou; Tianxiang Gu; Lai Wei; Tao Hong; Chunsheng Wang
Journal:  Front Cardiovasc Med       Date:  2021-12-13

7.  One-year outcome with a bovine pericardial valve.

Authors:  Jinmiao Chen; Chen He; Minzhi Lv; Yingqiang Guo; Liang Tao; Tao Hong; Chunsheng Wang
Journal:  JTCVS Open       Date:  2020-04-21

8.  Mid-term follow-up after aortic valve replacement with the Carpentier Edwards Magna Ease prosthesis.

Authors:  Taufiek K Rajab; Jason M Ali; Jules Hernández-Sánchez; Jennifer Mackie; Vincenzo Grimaudo; Silvia Sinichino; Christine Mills; Bushra Rana; John Dunning; Yasir Abu-Omar
Journal:  J Cardiothorac Surg       Date:  2020-08-03       Impact factor: 1.637

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.