Literature DB >> 20230770

Hydrogen peroxide biosensor based on a myoglobin/hydrophilic room temperature ionic liquid film.

Afsaneh Safavi1, Fatemeh Farjami.   

Abstract

The composite film based on Nafion and hydrophilic room temperature ionic liquid (RTIL) 1-butyl-3-methyl-imidazolium chloride ([bmim]Cl) was used as an immobilization matrix to entrap myoglobin (Mb). The study of ionic liquid (IL)-Mb interaction by ultraviolet-visible (UV-vis) spectroscopy showed that Mb retains its native conformation in the presence of IL. The immobilized Mb displayed a pair of well-defined cyclic voltammetric peaks with a formal potential (E(o)(')) of -0.35 V in a 0.1 M phosphate buffer solution (PBS) of pH 7.0. The immobilized Mb exhibited excellent electrocatalytic response to the reduction of hydrogen peroxide, based on which a mediator-free amperometric biosensor for hydrogen peroxide was designed. The linear range for the determination of hydrogen peroxide was from 1.0 to 180 microM with a detection limit of 0.14 microM at a signal/noise ratio of 3. The apparent Michaelis constant (K(m)(app)) for the electrocatalytic reaction was 22.6 microM. The stability, repeatability, and selectivity of the sensor were evaluated. The proposed biosensor has a lower detection limit than many other IL-heme protein-based biosensors and is free from common interference in hydrogen peroxide biosensors. 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20230770     DOI: 10.1016/j.ab.2010.03.013

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

Review 1.  Electrochemical sensors and biosensors.

Authors:  Danielle W Kimmel; Gabriel LeBlanc; Mika E Meschievitz; David E Cliffel
Journal:  Anal Chem       Date:  2011-11-11       Impact factor: 6.986

Review 2.  Ionic Liquid-Based Polymer Nanocomposites for Sensors, Energy, Biomedicine, and Environmental Applications: Roadmap to the Future.

Authors:  Kirti Mishra; Nishu Devi; Samarjeet Singh Siwal; Qibo Zhang; Walaa F Alsanie; Fabrizio Scarpa; Vijay Kumar Thakur
Journal:  Adv Sci (Weinh)       Date:  2022-07-19       Impact factor: 17.521

Review 3.  Fabrication of Electrochemical-Based Bioelectronic Device and Biosensor Composed of Biomaterial-Nanomaterial Hybrid.

Authors:  Mohsen Mohammadniaei; Chulhwan Park; Junhong Min; Hiesang Sohn; Taek Lee
Journal:  Adv Exp Med Biol       Date:  2018       Impact factor: 2.622

Review 4.  Disposable biosensors based on metal nanoparticles.

Authors:  S Malathi; I Pakrudheen; S Narayana Kalkura; T J Webster; S Balasubramanian
Journal:  Sens Int       Date:  2022-03-02

5.  Immobilization of myoglobin on Au nanoparticle-decorated carbon nanotube/polytyramine composite as a mediator-free H2O2 and nitrite biosensor.

Authors:  A T Ezhil Vilian; Vediyappan Veeramani; Shen-Ming Chen; Rajesh Madhu; Cheol Hwan Kwak; Yun Suk Huh; Young-Kyu Han
Journal:  Sci Rep       Date:  2015-12-17       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.