Literature DB >> 20230701

Biomechanical stability of intramedullary technique for fixation of joint depressed calcaneus fracture.

Joshua D Nelson1, Terence E McIff, Patrick G Moodie, Jamey L Iverson, Greg A Horton.   

Abstract

BACKGROUND: Internal fixation of the os calcis is often complicated by prolonged soft tissue management and posterior facet disruption. An ideal calcaneal construct would include minimal hardware prominence, sturdy posterior facet fixation and nominal soft tissue disruption. The purpose of this study was to develop such a construct and provide a biomechanical analysis comparing our technique to a standard internal fixation technique. METHODS AND MATERIALS: Twenty fresh-frozen cadaver calcanei were used to create a reproducible Sanders type-IIB calcaneal fracture pattern. One calcaneus of each pair was randomly selected to be fixed using our compressive headless screw technique. The contralateral matched calcaneus was fixed with a nonlocking calcaneal plate in a traditional fashion. Each calcaneus was cyclically loaded at a frequency of 1 Hz for 4000 cycles using an increasing force from 250 N to 1000 N. An Optotrak motion capturing system was used to detect relative motion of the three fracture fragments at eight different points along the fracture lines. Horizontal separation and vertical displacement at the fracture lines was recorded, as well as relative rotation at the primary fracture line.
RESULTS: When the data were averaged, there was more horizontal displacement at the primary fracture line of the plate and screw construct compared to the headless screw construct. The headless screw construct also had less vertical displacement at the primary fracture line at every load. On average those fractures fixed with the headless screw technique had less rotation than those fixed with the side plate technique.
CONCLUSION: A new headless screw technique for calcaneus fracture fixation was shown to provide stability as good as, or better than, a standard side plating technique under the axial loading conditions of our model. Although further testing is needed, the stability of the proposed technique is similar to that typically provided by intramedullary fixation. CLINICAL RELEVANCE: This fixation technique provides a biomechanically stable construct with the potential for a minimally invasive approach and improved post-operative soft tissue healing.

Entities:  

Mesh:

Year:  2010        PMID: 20230701     DOI: 10.3113/FAI.2010.0229

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  8 in total

1.  Percutaneous fixation of intraarticular joint-depression calcaneal fractures with different screw configurations - a biomechanical human cadaveric analysis.

Authors:  Stoyan Ivanov; Aleksandar Stefanov; Ivan Zderic; Christian Rodemund; Tim Schepers; Dominic Gehweiler; Jan Dauwe; Torsten Pastor; Biser Makelov; Dimitur Raykov; Geoff Richards; Boyko Gueorguiev
Journal:  Eur J Trauma Emerg Surg       Date:  2022-03-07       Impact factor: 2.374

2.  Three-dimensional computed tomography analysis and functional results of calcaneal fractures treated by an intramedullary nail.

Authors:  Antoine Fourgeaux; John Estens; Thierry Fabre; Olivier Laffenetre; Julien Lucas Y Hernandez
Journal:  Int Orthop       Date:  2019-08-01       Impact factor: 3.075

3.  Articular calcaneal fractures: open or minimally invasive surgery, when the medial wall reduction is obtained percutaneously from the lateral side.

Authors:  Hao Xu; Ruixing Hou; Jihui Ju; Yuefei Liu; Lucheng Chen
Journal:  Int Orthop       Date:  2021-08-01       Impact factor: 3.075

4.  Screw tip augmentation leads to improved primary stability in the minimally invasive treatment of displaced intra-articular fractures of the calcaneus: a biomechanical study.

Authors:  Martin Eichinger; Alexander Brunner; Hannes Stofferin; Andreas Bölderl; Michael Blauth; Werner Schmölz
Journal:  Int Orthop       Date:  2018-10-10       Impact factor: 3.075

5.  Stress shielding analysis on easy step staple prosthesis for calcaneus fractures.

Authors:  V Filardi
Journal:  J Orthop       Date:  2019-09-12

6.  Surgical Treatment of Sanders Type 2 Calcaneal Fractures Using a Sinus Tarsi Approach.

Authors:  Chul Hyun Park; Dong Yeol Lee
Journal:  Indian J Orthop       Date:  2017 Jul-Aug       Impact factor: 1.251

7.  Reduction and functional outcome of open reduction plate fixation versus minimally invasive reduction with percutaneous screw fixation for displaced calcaneus fracture: a retrospective study.

Authors:  Ye Peng; Jianheng Liu; Gongzi Zhang; Xinran Ji; Wei Zhang; Lihai Zhang; Peifu Tang
Journal:  J Orthop Surg Res       Date:  2019-05-09       Impact factor: 2.359

8.  The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study.

Authors:  Ming Ni; Jiong Mei; Kun Li; Wenxin Niu; Ming Zhang
Journal:  Biomed Eng Online       Date:  2018-05-02       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.