Literature DB >> 20227914

Miniaturized electroencephalographic scalp electrode for optimal wearing comfort.

Vadim V Nikulin1, Jewgeni Kegeles, Gabriel Curio.   

Abstract

OBJECTIVE: Current mainstream EEG electrode setups permit efficient recordings, but are often bulky and uncomfortable for subjects. Here we introduce a novel type of EEG electrode, which is designed for an optimal wearing comfort. The electrode is referred to as C-electrode where "C" stands for comfort.
METHODS: The C-electrode does not require any holder/cap for fixation on the head nor does it use traditional pads/lining of disposable electrodes - thus, it does not disturb subjects. Fixation of the C-electrode on the scalp is based entirely on the adhesive interaction between the very light C-electrode/wire construction (<35 mg) and a droplet of EEG paste/gel. Moreover, because of its miniaturization, both C-electrode (diameter 2-3mm) and a wire (diameter approximately 50 microm) are minimally (or not at all) visible to an external observer. EEG recordings with standard and C-electrodes were performed during rest condition, self-paced movements and median nerve stimulation.
RESULTS: The quality of EEG recordings for all three types of experimental conditions was similar for standard and C-electrodes, i.e., for near-DC recordings (Bereitschaftspotential), standard rest EEG spectra (1-45 Hz) and very fast oscillations approximately 600 Hz (somatosensory evoked potentials). The tests showed also that once being placed on a subject's head, C-electrodes can be used for 9h without any loss in EEG recording quality. Furthermore, we showed that C-electrodes can be effectively utilized for Brain-Computer Interfacing. C-electrodes proved to posses a high stability of mechanical fixation (stayed attached with 2.5 g accelerations). Subjects also reported not having any tactile sensations associated with wearing of C-electrodes.
CONCLUSION: C-electrodes provide optimal wearing comfort without any loss in the quality of EEG recordings. SIGNIFICANCE: We anticipate that C-electrodes can be used in a wide range of clinical, research and emerging neuro-technological environments. Copyright 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20227914     DOI: 10.1016/j.clinph.2010.02.008

Source DB:  PubMed          Journal:  Clin Neurophysiol        ISSN: 1388-2457            Impact factor:   3.708


  13 in total

1.  Compliant head probe for positioning electroencephalography electrodes and near-infrared spectroscopy optodes.

Authors:  Paolo Giacometti; Solomon G Diamond
Journal:  J Biomed Opt       Date:  2013-02       Impact factor: 3.170

2.  Heart rate variability for evaluating vigilant attention in partial chronic sleep restriction.

Authors:  Andreas Henelius; Mikael Sallinen; Minna Huotilainen; Kiti Müller; Jussi Virkkala; Kai Puolamäki
Journal:  Sleep       Date:  2014-07-01       Impact factor: 5.849

Review 3.  [Mobile seizure monitoring in epilepsy patients].

Authors:  A Schulze-Bonhage; S Böttcher; M Glasstetter; N Epitashvili; E Bruno; M Richardson; K V Laerhoven; M Dümpelmann
Journal:  Nervenarzt       Date:  2019-12       Impact factor: 1.214

4.  Exploring miniaturized EEG electrodes for brain-computer interfaces. An EEG you do not see?

Authors:  Martin G Bleichner; Micha Lundbeck; Matthias Selisky; Falk Minow; Manuela Jäger; Reiner Emkes; Stefan Debener; Maarten De Vos
Journal:  Physiol Rep       Date:  2015-04

5.  Is Neural Activity Detected by ERP-Based Brain-Computer Interfaces Task Specific?

Authors:  Markus A Wenzel; Inês Almeida; Benjamin Blankertz
Journal:  PLoS One       Date:  2016-10-28       Impact factor: 3.240

Review 6.  The Berlin Brain-Computer Interface: Progress Beyond Communication and Control.

Authors:  Benjamin Blankertz; Laura Acqualagna; Sven Dähne; Stefan Haufe; Matthias Schultze-Kraft; Irene Sturm; Marija Ušćumlic; Markus A Wenzel; Gabriel Curio; Klaus-Robert Müller
Journal:  Front Neurosci       Date:  2016-11-21       Impact factor: 4.677

7.  Signal Quality Evaluation of Emerging EEG Devices.

Authors:  Thea Radüntz
Journal:  Front Physiol       Date:  2018-02-14       Impact factor: 4.566

8.  Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear.

Authors:  Stefan Debener; Reiner Emkes; Maarten De Vos; Martin Bleichner
Journal:  Sci Rep       Date:  2015-11-17       Impact factor: 4.379

9.  Target Speaker Detection with Concealed EEG Around the Ear.

Authors:  Bojana Mirkovic; Martin G Bleichner; Maarten De Vos; Stefan Debener
Journal:  Front Neurosci       Date:  2016-07-27       Impact factor: 4.677

10.  Concealed, Unobtrusive Ear-Centered EEG Acquisition: cEEGrids for Transparent EEG.

Authors:  Martin G Bleichner; Stefan Debener
Journal:  Front Hum Neurosci       Date:  2017-04-07       Impact factor: 3.169

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.