Literature DB >> 20220249

Improvement of olfactometric measurement accuracy and repeatability by optimization of panel selection procedures.

L Capelli1, S Sironi, R Del Rosso, P Céntola, S Bonati.   

Abstract

The EN 13725:2003, which standardizes the determination of odour concentration by dynamic olfactometry, fixes the limits for panel selection in terms of individual threshold towards a reference gas (n-butanol in nitrogen) and of standard deviation of the responses. Nonetheless, laboratories have some degrees of freedom in developing their own procedures for panel selection and evaluation. Most Italian olfactometric laboratories use a similar procedure for panel selection, based on the repeated analysis of samples of n-butanol at a concentration of 60 ppm. The first part of this study demonstrates that this procedure may originate a sort of "smartening" of the assessors, which means that they become able to guess the right answers in order to maintain their qualification as panel members, independently from their real olfactory perception. For this reason, the panel selection procedure has been revised with the aim of making it less repetitive, therefore preventing the possibility for panel members to be able to guess the best answers in order to comply with the selection criteria. The selection of new panel members and the screening of the active ones according to this revised procedure proved this new procedure to be more selective than the "standard" one. Finally, the results of the tests with n-butanol conducted after the introduction of the revised procedure for panel selection and regular verification showed an effective improvement of the laboratory measurement performances in terms of accuracy and precision.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20220249     DOI: 10.2166/wst.2010.023

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  7 in total

Review 1.  Odour detection methods: olfactometry and chemical sensors.

Authors:  Magda Brattoli; Gianluigi de Gennaro; Valentina de Pinto; Annamaria Demarinis Loiotile; Sara Lovascio; Michele Penza
Journal:  Sensors (Basel)       Date:  2011-05-16       Impact factor: 3.576

2.  Ammonia diffusion through Nalophan double bags: effect of concentration gradient reduction.

Authors:  Selena Sironi; Lidia Eusebio; Laura Capelli; Emanuela Boiardi; Renato Del Rosso
Journal:  ScientificWorldJournal       Date:  2014-11-24

3.  H2S Loss through Nalophan™ Bags: Contributions of Adsorption and Diffusion.

Authors:  Lidia Eusebio; Laura Capelli; Selena Sironi
Journal:  ScientificWorldJournal       Date:  2017-06-27

Review 4.  Odor sampling: techniques and strategies for the estimation of odor emission rates from different source types.

Authors:  Laura Capelli; Selena Sironi; Renato Del Rosso
Journal:  Sensors (Basel)       Date:  2013-01-15       Impact factor: 3.576

5.  Development of an electronic nose for environmental odour monitoring.

Authors:  Licinia Dentoni; Laura Capelli; Selena Sironi; Renato Del Rosso; Sonia Zanetti; Matteo Della Torre
Journal:  Sensors (Basel)       Date:  2012-10-25       Impact factor: 3.576

6.  Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants.

Authors:  Jacek Gebicki; Hubert Byliński; Jacek Namieśnik
Journal:  Environ Monit Assess       Date:  2015-12-15       Impact factor: 2.513

7.  Electronic Nose Testing Procedure for the Definition of Minimum Performance Requirements for Environmental Odor Monitoring.

Authors:  Lidia Eusebio; Laura Capelli; Selena Sironi
Journal:  Sensors (Basel)       Date:  2016-09-21       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.