Literature DB >> 20219771

Valve replacement for aortic stenosis normalizes subendocardial function in patients with normal ejection fraction.

Per Lindqvist1, Gani Bajraktari, Roberta Molle, Elizabetta Palmerini, Anders Holmgren, Sergio Mondillo, Michael Y Henein.   

Abstract

AIMS: Long-standing aortic stenosis (AS) causes various degrees of left ventricular (LV) dysfunction, which may improve after valve replacement. The aim of this study was to assess the nature of LV subendocardial abnormalities in AS and their response to valve replacement (AVR). METHODS AND
RESULTS: We studied 41 consecutive symptomatic patients (age 64 +/- 13 years) with severe AS, normal LV ejection fraction (EF), but no obstructive coronary artery disease before, a week after AVR, and 6 months after AVR. LV subendocardial function was studied from recordings of long-axis M-mode (amplitude), tissue-Doppler (myocardial velocities) and speckle tracking (myocardial strain) echocardiographic techniques. Results were compared with those from 20 age- and gender-matched controls. In patients, LV dimensions and markers of asynchrony, total isovolumic time (t-IVT), and Tei index were not different from controls before AVR and remained unchanged afterwards. LV lateral long-axis amplitude, as well as lateral and septal systolic velocities and strain, were reduced (P < 0.001 for all) and E/E' was modestly raised. Lateral long-axis amplitude, systolic and diastolic velocities normalized within a week of AVR but strain lagged behind until 6 months later. The reduced septal long-axis amplitude remained permanently unchanged (NS) despite the early normalization of its systolic velocities (P < 0.001) and strain (P < 0.001). LV mass normalized at 6 months after AVR (P < 0.005).
CONCLUSIONS: In patients with severe AS and maintained LV ejection fraction, subendocardial function is globally abnormal showing reduced amplitude of motion, velocities, and strain. The different response of its components suggests an evidence for differential reverse remodelling, irrespective of myocardial mass regression.

Entities:  

Mesh:

Year:  2010        PMID: 20219771     DOI: 10.1093/ejechocard/jeq026

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  9 in total

1.  Acute regional improvement of myocardial function after interventional transfemoral aortic valve replacement in aortic stenosis: a speckle tracking echocardiography study.

Authors:  Sebastian Schattke; Gerd Baldenhofer; Ines Prauka; Kun Zhang; Michael Laule; Verena Stangl; Wasiem Sanad; Sebastian Spethmann; Adrian C Borges; Gert Baumann; Karl Stangl; Fabian Knebel
Journal:  Cardiovasc Ultrasound       Date:  2012-03-26       Impact factor: 2.062

2.  A Comparison of Global Longitudinal, Circumferential, and Radial Strain to Predict Outcomes After Cardiac Surgery.

Authors:  Kan Zhang; Richard Sheu; Nicole M Zimmerman; Andrej Alfirevic; Shiva Sale; A Marc Gillinov; Andra E Duncan
Journal:  J Cardiothorac Vasc Anesth       Date:  2018-10-24       Impact factor: 2.628

3.  Impact of stroke volume on severe aortic stenosis in patients with normal left ventricular function.

Authors:  Shinya Fukui; Yumi Kakizawa; Kazuma Handa; Tomohiko Sakamoto; Yukitoshi Shirakawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2019-07-08

Review 4.  Perioperative assessment of myocardial deformation.

Authors:  Andra E Duncan; Andrej Alfirevic; Daniel I Sessler; Zoran B Popovic; James D Thomas
Journal:  Anesth Analg       Date:  2014-03       Impact factor: 5.108

5.  Speckle tracking echocardiography derived 2-dimensional myocardial strain predicts left ventricular function and mass regression in aortic stenosis patients undergoing aortic valve replacement.

Authors:  Adam Staron; Manish Bansal; Piyush Kalakoti; Ayumi Nakabo; Zbigniew Gasior; Piotr Pysz; Krystian Wita; Marek Jasinski; Partho P Sengupta
Journal:  Int J Cardiovasc Imaging       Date:  2012-11-30       Impact factor: 2.357

6.  The Early Variation of Left Ventricular Strain after Aortic Valve Replacement by Three-Dimensional Echocardiography.

Authors:  Yongle Chen; Zhiqi Zhang; Leilei Cheng; Li Fan; Chunsheng Wang; Xianhong Shu
Journal:  PLoS One       Date:  2015-10-16       Impact factor: 3.240

Review 7.  Cardiac mechanics evaluated by speckle tracking echocardiography.

Authors:  Maria Cristina Donadio Abduch; Adriano Mesquita Alencar; Wilson Mathias; Marcelo Luiz de Campos Vieira
Journal:  Arq Bras Cardiol       Date:  2014-04       Impact factor: 2.000

8.  Speckle Tracking Echocardiographic Assessment of Left Ventricular Function by Myocardial Strain Before and After Aortic Valve Replacement.

Authors:  Gajinder Pal Singh Kaler; Rakesh Mahla; Himanshu Mahla; Sarita Choudhary; Gurdarshan Singh; Raghuveer Prasad Patel; Navjot Kaur Kaler
Journal:  J Saudi Heart Assoc       Date:  2022-01-05

9.  The clinical significance of the incorporation of tissue Doppler imaging into low-dose Dobutamine stress echocardiography in patients with aortic stenosis prior to Transcatheter aortic valve implantation.

Authors:  Sahrai Saeed; Joerg Kellermair; Jon Herstad; Øyvind Bleie
Journal:  BMC Cardiovasc Disord       Date:  2020-09-14       Impact factor: 2.298

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.