Literature DB >> 20219424

Effects of heated humidification on nasal inflammation in a CPAP rat model.

Brígida Martínez-Vidal1, Ramon Farré, Josep M Montserrat, Marta Torres, Isaac Almendros, Francina Aguilar, Cristina Embid, Isabel Vilaseca.   

Abstract

BACKGROUND: Rhinitis is a potential side effect of nasal continuous positive airway pressure (nCPAP). Heated Humidification (HH) is applied to treat rhinitic symptoms, but its usefulness is controversial. Confounding factors such as previous rhinitis or nasal obstruction make it difficult to draw definitive conclusions. Animal models could therefore be useful.
OBJECTIVES: To study the effects of HH as a mechanism that may reduce nasal inflammation during nCPAP application in the presence or absence of an oral leak (OL).
METHODS: Prospective controlled animal study. Setting I: Sixty Sprague-Dawley rats were distributed into noCPAP (naïve), sham-CPAP with HH, 5 and 10cm H(2)O nCPAP, and 10cm H(2)O nCPAP with HH for 5h. Setting II: Thirty-three rats were exposed to nCPAP, nCPAP with a controlled OL, and nCPAP with controlled OL and HH (n=11 each). The degree of nasal inflammation was assessed by directly evaluating the percentage of neutrophils in the nasal mucosa.
RESULTS: Percentage of neutrophils was higher after 5h of 10cm nCPAP compared to the control group (0.96+/-0.26% vs. 0.18+/-0.05%; p=0.001). When HH was applied, the percentage of neutrophils did not differ from that observed in the nCPAP group. The addition of a controlled OL, did not show significant differences in the neutrophils count compared to nCPAP alone (0.75+/-0.19% vs. 0.83+/-0.29%; p=0.70). Moreover, the application of HH to the rat with OL did not change the percentage of neutrophils.
CONCLUSIONS: HH applied to an acute rat model of nCPAP with and without a controlled OL does not seem to reduce nasal inflammation. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20219424     DOI: 10.1016/j.sleep.2009.09.010

Source DB:  PubMed          Journal:  Sleep Med        ISSN: 1389-9457            Impact factor:   3.492


  2 in total

1.  Effects of CPAP in patients with obstructive apnoea: is the presence of allergic rhinitis relevant?

Authors:  A Cisternas; F Aguilar; J M Montserrat; M Àvila; M Torres; A Iranzo; J Berenguer; I Vilaseca
Journal:  Sleep Breath       Date:  2017-05-10       Impact factor: 2.816

2.  Effect of humidified versus nonhumidified CPAP on inflammatory response and nasopharyngeal symptoms in healthy participants.

Authors:  Hajed M Al-Otaibi; Mohammed D Alahmari; Thekra N Al-Maqati; Abdullah Ghazwani
Journal:  Can J Respir Ther       Date:  2020-07-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.