Literature DB >> 20214423

DuraHeart magnetically levitated centrifugal left ventricular assist system for advanced heart failure patients.

Michiel Morshuis1, Michael Schoenbrodt, Chisato Nojiri, Daniela Roefe, Sebastian Schulte-Eistrup, Jochen Boergermann, Jan F Gummert, Latif Arusoglu.   

Abstract

The implantable left ventricular assist system (LVAS) using pulsatile pump technology has become an established therapeutic option for advanced heart failure patients. However, there have been technological limitations in some older designs, including a high incidence of infection and mechanical failures associated with moving parts, and the large size of both implantable pump and percutaneous cable. A smaller rotary blood pump emerged as a possible alternative to a large pulsatile pump to overcome some of these limitations. The technological advancement that defines the third-generation LVAS was the elimination of all mechanical contacts between the impeller and the drive mechanism. The DuraHeart LVAS is the world's first third-generation implantable LVAS to obtain market approval (CE-mark), which combines a centrifugal pump and active magnetic levitation. The initial clinical experience with the DuraHeart LVAS in Europe demonstrated that it provided significantly improved survival (85% at 6 months and 79% at 1 year), reduced adverse event rates and long-term device reliability (freedom from device replacement at 2 years: 96 +/- 3%) over pulsatile LVAS.

Entities:  

Mesh:

Year:  2010        PMID: 20214423     DOI: 10.1586/erd.09.68

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  5 in total

1.  Use of DuraHeart® support for more than 1 year as the first successful bridge to heart transplantation in Japan.

Authors:  Chitaru Kurihara; Minoru Ono; Takashi Nishimura; Aya Saito; Tsuyoshi Taketani; Motoyuki Hisagi; Kan Nawata; Osamu Kinoshita; Tetsurou Morota; Noboru Motomura; Shunei Kyo
Journal:  J Artif Organs       Date:  2010-12-29       Impact factor: 1.731

2.  Exchange of DuraHeart left ventricular assist device via a subcostal approach.

Authors:  Masashi Kawamura; Taichi Sakaguchi; Shigeru Miyagawa; Hiroyuki Nishi; Yasushi Yoshikawa; Satsuki Fukushima; Shunsuke Saito; Takayoshi Ueno; Toru Kuratani; Yoshiki Sawa
Journal:  J Artif Organs       Date:  2011-09-16       Impact factor: 1.731

3.  Viscosity-adjusted estimation of pressure head and pump flow with quasi-pulsatile modulation of rotary blood pump for a total artificial heart.

Authors:  Terumi Yurimoto; Shintaro Hara; Takashi Isoyama; Itsuro Saito; Toshiya Ono; Yusuke Abe
Journal:  J Artif Organs       Date:  2016-03-29       Impact factor: 1.731

Review 4.  Updates on Device-Based Therapies for Patients with Heart Failure.

Authors:  Jad Al Danaf; Javed Butler; Amin Yehya
Journal:  Curr Heart Fail Rep       Date:  2018-04

5.  Contemporary outcomes of continuous-flow left ventricular assist devices-a systematic review.

Authors:  Nicholas McNamara; Harry Narroway; Michael Williams; John Brookes; James Farag; David Cistulli; Paul Bannon; Silvana Marasco; Evgenij Potapov; Antonio Loforte
Journal:  Ann Cardiothorac Surg       Date:  2021-03
  5 in total