Literature DB >> 20213340

(99m)Tc-DTPA dynamic SPECT and CT volumetry for measuring split renal function in live kidney donors.

Chihoko Miyazaki1, Hiroshi Harada, Noriyuki Shuke, Atsutaka Okizaki, Masayoshi Miura, Tetsuo Hirano.   

Abstract

OBJECTIVES: Split renal function (SRF) estimated from the posterior view of (99m)Tc-diethylenetriaminepentaacetic acid planar scintigraphy (DTPA/P) is not sufficiently accurate even after correction for kidney depth by computed tomography (CT). To obtain more accurate SRF using (99m)Tc-DTPA, dynamic SPECT method was carried out for the initial 5 min after bolus injection of (99m)Tc-DTPA (DTPA/SPECT). Also SRF was evaluated from the renal volume measured by CT. We compared the results with (99m)Tc-dimercaptosuccinic acid SPECT (DMSA/SPECT).
METHODS: In 60 consecutive live kidney donors, 30 DTPA/P, 30 DTPA/SPECT, 60 (99m)Tc-DMSA/SPECT, and 60 CT studies were performed. In the DTPA/P studies, SRF was calculated from the posterior image recorded during 2-3-min postinjection with attenuation correction for kidney depth measured by CT. In the DTPA/SPECT studies, SPECT images were acquired continuously for 5 min with a dual-headed gamma camera. In (99m)Tc-DMSA scintigraphy, DMSA/SPECT images were acquired 3-h postinjection. The SRF on both SPECT studies was calculated from the total counts of each kidney. In the DTPA/SPECT study, SRF was evaluated on the three images summed for 1 min: 1-2 min (DTPA/SPECT1-2), 2-3 min (DTPA/SPECT2-3), and 1-3 min (DTPA/SPECT1-3). In the CT examination, to assess the global renal volume, the axial images in the excretory phase were chosen. Renal contours were identified on each image, and the areas (cm(2)) of these regions were summed and multiplied by the slice thickness (10 mm) to yield global renal volume (ml). Right renal function from DTPA/P, DTPA/SPECT, and CT were compared with that from DMSA/SPECT as a reference.
RESULTS: Correlation coefficients of the right renal function between DMSA/SPECT and DTPA/P, DTPA/SPECT2-3, and CT were 0.663, 0.849 and 0.907, respectively (P < 0.0001). The differences between DMSA/SPECT and DTPA/P, DTPA/SPECT2-3 and CT were 2.42 +/- 3.878, 0.867 +/- 1.672, and -0.421 +/- 1.077% (mean +/- SD), respectively.
CONCLUSION: SRF derived from DTPA/SPECT showed a better correlation with DMSA/SPECT and significantly fewer errors (P < 0.05) than DTPA/P. A significant strong correlation was observed between SRF from DMSA/SPECT and CT, indicating the utility of CT renal volumetry for evaluating SRF.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20213340     DOI: 10.1007/s12149-010-0349-y

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  6 in total

1.  A simple method to estimate renal volume from computed tomography.

Authors:  Rodney H Breau; Edward Clark; Bryan Bruner; Patrick Cervini; Thomas Atwell; Greg Knoll; Bradley C Leibovich
Journal:  Can Urol Assoc J       Date:  2013 May-Jun       Impact factor: 1.862

2.  Fast direct estimation of the blood input function and myocardial time activity curve from dynamic SPECT projections via reduction in spatial and temporal dimensions.

Authors:  Yunlong Zan; Rostyslav Boutchko; Qiu Huang; Biao Li; Kewei Chen; Grant T Gullberg
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

3.  Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method.

Authors:  Shan You; XianWu Ma; ChangZhu Zhang; Qiang Li; WenWei Shi; Jing Zhang; XiaoDong Yuan
Journal:  Eur Radiol       Date:  2017-10-02       Impact factor: 5.315

4.  Estimation of Split Renal Function With 99mTc-DMSA SPECT: Comparison Between 3D Volumetric Assessment and 2D Coronal Projection Imaging.

Authors:  Xinhua Cao; Xiaoyin Xu; Frederick D Grant; S Ted Treves
Journal:  AJR Am J Roentgenol       Date:  2016-09-13       Impact factor: 3.959

5.  Evaluation of Renal Function in Obstructed Ureter Model Using 99mTc-DMSA.

Authors:  Seok Jin Jang; Byung Soo Choi; Seok Hwa Choi
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

6.  Can Split Renal Volume Assessment by Computed Tomography Replace Nuclear Split Renal Function in Living Kidney Donor Evaluations? A Systematic Review and Meta-Analysis.

Authors:  Steven Habbous; Carlos Garcia-Ochoa; Gary Brahm; Chris Nguan; Amit X Garg
Journal:  Can J Kidney Health Dis       Date:  2019-09-19
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.