Literature DB >> 2021174

The elastic properties of the lens capsule in capsulorhexis.

E I Assia1, D J Apple, J C Tsai, E S Lim.   

Abstract

We investigated the ability of the anterior lens capsule to stretch and allow removal of lens substance and intraocular lens implantation through a continuous circular capsulorhexis. Capsulorhexis of various sizes (2.5 to 7.5 mm) were performed in 50 eyes obtained post mortem from 31 patients. The nucleus and cortex were removed by either phacoemulsification (35 eyes) or manual extracapsular cataract extraction (15 eyes). The opening of the capsule was then gradually enlarged, using a modified caliper with two pins attached to its tips, until the margins were torn. The capsule was torn when the circumference at the time of rupture was 1.6 times larger than the circumference of the original circular capsulectomy or 5.0 times larger than the diameter of the capsulectomy. Manual extraction of a lens nucleus with profile circumference (sagittal or anteroposterior) of 18.0 to 22.0 mm can be performed through a 5.5-mm opening and a 6.0- to 7.0-mm optic intraocular lens (profile circumference of 13.0 to 17.0 mm) can be implanted through a 4.5-mm capsulectomy.

Entities:  

Mesh:

Year:  1991        PMID: 2021174     DOI: 10.1016/s0002-9394(14)73710-9

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  10 in total

1.  [History of the development of intraocular lenses].

Authors:  G U Auffarth; D J Apple
Journal:  Ophthalmologe       Date:  2001-11       Impact factor: 1.059

2.  Capsulorhexis: Pearls and pitfalls.

Authors:  Mehrdad Mohammadpour; Reza Erfanian; Nasser Karimi
Journal:  Saudi J Ophthalmol       Date:  2012-01

3.  Continuous curvilinear (circular) capsulorhexis and planned extracapsular cataract extraction--are they compatible?

Authors:  M Pande
Journal:  Br J Ophthalmol       Date:  1993-03       Impact factor: 4.638

4.  Anterior capsulotomy with a pulsed-electron avalanche knife.

Authors:  Daniel Palanker; Hiroyuki Nomoto; Philip Huie; Alexander Vankov; David F Chang
Journal:  J Cataract Refract Surg       Date:  2010-01       Impact factor: 3.351

5.  Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

Authors:  D J Apple
Journal:  Trans Am Ophthalmol Soc       Date:  2000

6.  Effects of trypan blue on corneal endothelium and anterior lens capsule in albino wistar rats: An investigator-masked, controlled, two-period, experimental study.

Authors:  Seyhmus Ari; Ihsan Caça; Kaan Unlü; Yusuf Nergiz; Ihsan Aksit
Journal:  Curr Ther Res Clin Exp       Date:  2006-11

7.  A comparative study of the elastic properties of continuous tear curvilinear capsulorhexis versus capsulorhexis produced by radiofrequency endodiathermy.

Authors:  J Luck; A K Brahma; B A Noble
Journal:  Br J Ophthalmol       Date:  1994-05       Impact factor: 4.638

8.  Analysis of femtosecond laser assisted capsulotomy cutting edges and manual capsulorhexis using environmental scanning electron microscopy.

Authors:  Sebastiano Serrao; Giuseppe Lombardo; Giovanni Desiderio; Lucio Buratto; Domenico Schiano-Lomoriello; Marco Pileri; Marco Lombardo
Journal:  J Ophthalmol       Date:  2014-11-20       Impact factor: 1.909

9.  Capsulotomy and hydroprocedures for nucleus prolapse in manual small incision cataract surgery.

Authors:  Rengaraj Venkatesh; Kannusamy Veena; Ravilla D Ravindran
Journal:  Indian J Ophthalmol       Date:  2009 Jan-Feb       Impact factor: 1.848

10.  Flap motility as a sign of posterior capsule rupture in peripherally extended anterior capsular tears.

Authors:  Rohit Om Parkash; Shruti Mahajan; Vinod Biala; Tushya Om Parkash; Alhaj F Tasneem
Journal:  Clin Ophthalmol       Date:  2017-08-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.