Literature DB >> 20210950

An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.

Gary A Sod1, Laura M Riggs, Colin F Mitchell, Jeremy D Hubert, George S Martin.   

Abstract

OBJECTIVES: To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. STUDY
DESIGN: Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. SAMPLE POPULATION: Cadaveric adult equine forelimbs (n=15 pairs).
METHODS: For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05.
RESULTS: Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation.
CONCLUSION: The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. CLINICAL RELEVANCE: The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.

Entities:  

Mesh:

Year:  2010        PMID: 20210950     DOI: 10.1111/j.1532-950X.2009.00615.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  1 in total

1.  Comparison of limited-contact dynamic compression plate and locking compression plate constructs for proximal interphalangeal joint arthrodesis in the horse.

Authors:  Richard A Rocconi; James L Carmalt; Sarah N Sampson; Steve H Elder; Eric E Gilbert
Journal:  Can Vet J       Date:  2015-06       Impact factor: 1.008

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.