Literature DB >> 20210436

Magnetomotive laser speckle imaging.

Jeehyun Kim1, Junghwan Oh, Bernard Choi.   

Abstract

Laser speckle imaging (LSI) involves analysis of reflectance images collected during coherent optical excitation of an object to compute wide-field maps of tissue blood flow. An intrinsic limitation of LSI for resolving microvascular architecture is that its signal depends on relative motion of interrogated red blood cells. Hence, with LSI, small-diameter arterioles, venules, and capillaries are difficult to resolve due to the slow flow speeds associated with such vasculature. Furthermore, LSI characterization of subsurface blood flow is subject to blurring due to scattering, further limiting the ability of LSI to resolve or quantify blood flow in small vessels. Here, we show that magnetic activation of superparamagnetic iron oxide (SPIO) nanoparticles modulate the speckle flow index (SFI) values estimated from speckle contrast analysis of collected images. With application of an ac magnetic field to a solution of stagnant SPIO particles, an apparent increase in SFI is induced. Furthermore, with application of a focused dc magnetic field, a focal decrease in SFI values is induced. Magnetomotive LSI may enable wide-field mapping of suspicious tissue regions, enabling subsequent high-resolution optical interrogation of these regions. Similarly, subsequent photoactivation of intravascular SPIO nanoparticles could then be performed to induce selective photothermal destruction of unwanted vasculature.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20210436      PMCID: PMC2816991          DOI: 10.1117/1.3285612

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  31 in total

1.  Linear response range characterization and in vivo application of laser speckle imaging of blood flow dynamics.

Authors:  Bernard Choi; Julio C Ramirez-San-Juan; Justin Lotfi; J Stuart Nelson
Journal:  J Biomed Opt       Date:  2006 Jul-Aug       Impact factor: 3.170

2.  New insights into image processing of cortical blood flow monitors using laser speckle imaging.

Authors:  M Le Thinh; Joseph S Paul; H Al-Nashash; A Tan; A R Luft; F S Sheu; S H Ong
Journal:  IEEE Trans Med Imaging       Date:  2007-06       Impact factor: 10.048

3.  Simplified laser-speckle-imaging analysis method and its application to retinal blood flow imaging.

Authors:  Haiying Cheng; Timothy Q Duong
Journal:  Opt Lett       Date:  2007-08-01       Impact factor: 3.776

4.  The importance of long-term monitoring to evaluate the microvascular response to light-based therapies.

Authors:  Bernard Choi; Wangcun Jia; Jennifer Channual; Kristen M Kelly; Justin Lotfi
Journal:  J Invest Dermatol       Date:  2007-08-02       Impact factor: 8.551

5.  Magnetomotive contrast for in vivo optical coherence tomography.

Authors:  Amy Oldenburg; Farah Toublan; Kenneth Suslick; Alexander Wei; Stephen Boppart
Journal:  Opt Express       Date:  2005-08-22       Impact factor: 3.894

6.  Photothermal response of superparamagnetic iron oxide nanoparticles.

Authors:  Jihoon Kim; Junghwan Oh; Hyun Wook Kang; Marc D Feldman; Thomas E Milner
Journal:  Lasers Surg Med       Date:  2008-08       Impact factor: 4.025

7.  Quantitative intracellular magnetic nanoparticle uptake measured by live cell magnetophoresis.

Authors:  Ying Jing; Niladri Mal; P Stephen Williams; Maritza Mayorga; Marc S Penn; Jeffrey J Chalmers; Maciej Zborowski
Journal:  FASEB J       Date:  2008-08-25       Impact factor: 5.191

8.  Detection of magnetic nanoparticles in tissue using magneto-motive ultrasound.

Authors:  Junghwan Oh; Marc D Feldman; Jeehyun Kim; Chris Condit; Stanislav Emelianov; Thomas E Milner
Journal:  Nanotechnology       Date:  2006-08-01       Impact factor: 3.874

9.  Mild induced hypertension improves blood flow and oxygen metabolism in transient focal cerebral ischemia.

Authors:  Hwa Kyoung Shin; Masaki Nishimura; Phillip B Jones; Hakan Ay; David A Boas; Michael A Moskowitz; Cenk Ayata
Journal:  Stroke       Date:  2008-03-13       Impact factor: 7.914

10.  A modified mini-stroke model with region-directed reperfusion in rat cortex.

Authors:  Weihua Luo; Zhen Wang; Pengcheng Li; Shaoqun Zeng; Qingming Luo
Journal:  J Cereb Blood Flow Metab       Date:  2007-12-12       Impact factor: 6.200

View more
  6 in total

Review 1.  Magnetomotive molecular nanoprobes.

Authors:  Renu John; Stephen A Boppart
Journal:  Curr Med Chem       Date:  2011       Impact factor: 4.530

2.  Spatial versus temporal laser speckle contrast analyses in the presence of static optical scatterers.

Authors:  Julio C Ramirez-San-Juan; Caitlin Regan; Beatriz Coyotl-Ocelotl; Bernard Choi
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

3.  Visualization of in vitro deep blood vessels using principal component analysis based laser speckle imaging.

Authors:  Jose Angel Arias-Cruz; Roger Chiu; Hayde Peregrina-Barreto; Ruben Ramos-Garcia; Teresita Spezzia-Mazzocco; Julio C Ramirez-San-Juan
Journal:  Biomed Opt Express       Date:  2019-03-25       Impact factor: 3.732

4.  Improved speckle contrast optical coherence tomography angiography.

Authors:  Liwei Wang; Yuejie Li; Yilu Li; Kaining Li
Journal:  Am J Transl Res       Date:  2018-10-15       Impact factor: 4.060

5.  Photothermal laser speckle imaging.

Authors:  Caitlin Regan; Julio C Ramirez-San-Juan; Bernard Choi
Journal:  Opt Lett       Date:  2014-09-01       Impact factor: 3.776

Review 6.  Magnetic particles in motion: magneto-motive imaging and sensing.

Authors:  Kelsey P Kubelick; Mohammad Mehrmohammadi
Journal:  Theranostics       Date:  2022-01-24       Impact factor: 11.556

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.