Literature DB >> 20209200

A prospective randomized study on the immediate loading of mandibular overdentures supported by one or two implants: a 12-month follow-up report.

Mats Kronstrom1, Ben Davis, Robert Loney, Jack Gerrow, Lars Hollender.   

Abstract

PURPOSE: The purpose of the present study was to evaluate and compare treatment with mandibular overdentures supported by one or two implants placed and loaded immediately.
MATERIALS AND METHODS: Edentulous subjects with maxillary and mandibular complete dentures were recruited to participate in the study. All subjects received new maxillary and mandibular complete dentures, after which they were scheduled for implant surgery. Using a randomized sampling system, one or two implants were placed in the interforaminal area, and separate ball attachments were connected to the implants. The existing mandibular denture was relined, provided with retentive o-rings, and delivered the day of surgery. Subjects were seen for follow-up examinations after 3, 6, and 12 months, during which marginal bone levels and implant stability were measured. Survival rates were calculated and the data were analyzed statistically.
RESULTS: Thirty-six subjects (16 men and 20 women with a mean age of 53.2 years [range, 38 to 69 years]) received 55 implants. Seventeen subjects received one implant in the symphyseal area, and the other 19 received two implants in the canine positions. Ten implants in nine subjects failed during the observation period, and three subjects with two implants each withdrew from the study, resulting in a 12-month implant survival rate of 81.8%. Three subjects lost their only implant and one patient lost both implants. The remaining five subjects lost one of their two implants. Six of the failures occurred during the first month after placement.
CONCLUSION: Immediate loading of one or two separate implants by means of ball attachment-supported mandibular overdentures should be performed with caution, as a higher than expected implant failure rate was observed. No statistically significant differences in failure rates between the two groups were observed.

Entities:  

Mesh:

Year:  2010        PMID: 20209200

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  16 in total

Review 1.  Immediate loading of overdentures: systematic review.

Authors:  Marcelo Coelho Goiato; Lisiane Cristina Bannwart; Aldiéris Alves Pesqueira; Daniela Micheline dos Santos; Marcela Filié Haddad; Murillo Rezende Santos; Paula Uchoa Castilho
Journal:  Oral Maxillofac Surg       Date:  2013-07-05

2.  Does professional experience save teeth? A survey among prosthodontists.

Authors:  Shaza Bishti; Julia Lautensack; Jens C Türp; Stefan Wolfart
Journal:  Clin Oral Investig       Date:  2017-07-20       Impact factor: 3.573

Review 3.  The single midline implant in the edentulous mandible: a systematic review.

Authors:  Nicole Passia; Matthias Kern
Journal:  Clin Oral Investig       Date:  2014-05-29       Impact factor: 3.573

4.  Two Years Retrospective Evaluation of Overdenture Retained by Symphyseal Single Implant Using Two Types of Attachments.

Authors:  Hussien Abdelfattah Ismail; Ahmed I Mahrous; Fahad H Banasr; Tarek A Soliman; Yasser Baraka
Journal:  J Int Oral Health       Date:  2015-06

5.  A clinico radiographic study of immediate loading implants in rehabilitation of mandibular ridges.

Authors:  M Viswambaran; Vimal Arora; S H Gupta; R K Dhiman; N Thiruvalluvan
Journal:  Med J Armed Forces India       Date:  2014-08-22

6.  Pain and discomfort following immediate and delayed loading by overdentures in the single mandibular implant study (SMIS).

Authors:  T Mundt; N Passia; W Att; G Heydecke; S Freitag-Wolf; R G Luthardt; S Kappel; I K Konstantinidis; M Stiesch; S Wolfart; M Kern
Journal:  Clin Oral Investig       Date:  2016-08-12       Impact factor: 3.573

7.  Number of implants for mandibular implant overdentures: a systematic review.

Authors:  Jeong-Yol Lee; Ha-Young Kim; Sang-Wan Shin; S Ross Bryant
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

8.  A prospective study of early loaded single implant-retained mandibular overdentures: preliminary one-year results.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-03-15

9.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11

10.  Single dental implant retained mandibular complete dentures--influence of the loading protocol: study protocol for a randomized controlled trial.

Authors:  Nicole Passia; Miha Brezavšček; Elfriede Fritzer; Stefanie Kappel; Thomas Kern; Ralph G Luthardt; Nadine Frfr von Maltzahn; Torsten Mundt; Michael Rädel; Axel von Stein-Lausnitz; Matthias Kern
Journal:  Trials       Date:  2014-05-24       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.