BACKGROUND: Echocardiographic measurements of left ventricular (LV) mass, left atrial (LA) volume, and LV end-systolic volume (ESV) predict heart failure (HF) hospitalization and mortality. Indexing measurements by body size is thought to establish limits of normality among individuals varying in body habitus. The American Society of Echocardiography recommends dividing measurements by body surface area (BSA), but others have advocated alternative indexing methods. METHODS: Echocardiographic measurements were collected in 1024 ambulatory adults with coronary artery disease. LV mass, LA volume, and LV ESV were calculated using truncated ellipse method and biplane method of disk formulae. Comparison between raw measurements and measurements divided by indexing parameters was made by hazard ratios per standard deviation increase in variable and c-statistics for BSA, BSA(0.43), BSA(1.5), height, height(0.25), height(2), height(2.7), body weight (BW), BW(0.26), body mass index (BMI), and BMI(0.27). RESULTS: Mean LV mass was 192 +/- 57 g, mean LA volume was 65 +/- 24 mL, and mean LV ESV was 41 +/- 26 mL. Average height was 171 +/- 9 cm, average BSA was 1.94 +/- 0.22 m(2), and average BMI was 28.4 +/- 5.3 kg/m(2). At an average follow-up of 5.6 +/- 1.8 years, there were 148 HF hospitalizations, 71 cardiovascular (CV) deaths, and 269 all-cause deaths. There was excellent correlation between raw measurements and those indexed by height (r = 0.98-0.99), and moderate correlation between raw measurements and those indexed by BW (r = 0.73-0.94). C-statistics and hazard ratios per standard deviation increase in indexed variables were similar for HF hospitalization, CV mortality, and all-cause mortality. There were no significant differences among indexing methods in ability to predict outcomes. CONCLUSION: The choice of indexing method by parameters of BSA, height, BW, and BMI does not affect the clinical usefulness of LV mass, LA volume, and LV ESV in predicting HF hospitalization, CV mortality, or all-cause mortality among ambulatory adults with coronary artery disease. Continued use of BSA to index measurements of LV mass, LA volume, and LV ESV is acceptable. Copyright 2010 American Society of Echocardiography. All rights reserved.
BACKGROUND: Echocardiographic measurements of left ventricular (LV) mass, left atrial (LA) volume, and LV end-systolic volume (ESV) predict heart failure (HF) hospitalization and mortality. Indexing measurements by body size is thought to establish limits of normality among individuals varying in body habitus. The American Society of Echocardiography recommends dividing measurements by body surface area (BSA), but others have advocated alternative indexing methods. METHODS: Echocardiographic measurements were collected in 1024 ambulatory adults with coronary artery disease. LV mass, LA volume, and LV ESV were calculated using truncated ellipse method and biplane method of disk formulae. Comparison between raw measurements and measurements divided by indexing parameters was made by hazard ratios per standard deviation increase in variable and c-statistics for BSA, BSA(0.43), BSA(1.5), height, height(0.25), height(2), height(2.7), body weight (BW), BW(0.26), body mass index (BMI), and BMI(0.27). RESULTS: Mean LV mass was 192 +/- 57 g, mean LA volume was 65 +/- 24 mL, and mean LV ESV was 41 +/- 26 mL. Average height was 171 +/- 9 cm, average BSA was 1.94 +/- 0.22 m(2), and average BMI was 28.4 +/- 5.3 kg/m(2). At an average follow-up of 5.6 +/- 1.8 years, there were 148 HF hospitalizations, 71 cardiovascular (CV) deaths, and 269 all-cause deaths. There was excellent correlation between raw measurements and those indexed by height (r = 0.98-0.99), and moderate correlation between raw measurements and those indexed by BW (r = 0.73-0.94). C-statistics and hazard ratios per standard deviation increase in indexed variables were similar for HF hospitalization, CV mortality, and all-cause mortality. There were no significant differences among indexing methods in ability to predict outcomes. CONCLUSION: The choice of indexing method by parameters of BSA, height, BW, and BMI does not affect the clinical usefulness of LV mass, LA volume, and LV ESV in predicting HF hospitalization, CV mortality, or all-cause mortality among ambulatory adults with coronary artery disease. Continued use of BSA to index measurements of LV mass, LA volume, and LV ESV is acceptable. Copyright 2010 American Society of Echocardiography. All rights reserved.
Authors: K T Spencer; V Mor-Avi; J Gorcsan; A N DeMaria; T R Kimball; M J Monaghan; J E Perez; L Weinert; J Bednarz; K Edelman; O L Kwan; B Glascock; J Hancock; C Baumann; R M Lang Journal: Heart Date: 2001-03 Impact factor: 5.994
Authors: Bernice Ruo; John S Rumsfeld; Mark A Hlatky; Haiying Liu; Warren S Browner; Mary A Whooley Journal: JAMA Date: 2003-07-09 Impact factor: 56.272
Authors: Anna Peeters; Jan J Barendregt; Frans Willekens; Johan P Mackenbach; Abdullah Al Mamun; Luc Bonneux Journal: Ann Intern Med Date: 2003-01-07 Impact factor: 25.391
Authors: Michael A Rosenberg; Kristen K Patton; Nona Sotoodehnia; Maria G Karas; Jorge R Kizer; Peter J Zimetbaum; James D Chang; David Siscovick; John S Gottdiener; Richard A Kronmal; Susan R Heckbert; Kenneth J Mukamal Journal: Eur Heart J Date: 2012-09-12 Impact factor: 29.983
Authors: Michael M Hammond; Changyu Shen; Stephanie Li; Dhruv S Kazi; Marwa A Sabe; A Reshad Garan; Lawrence J Markson; Warren J Manning; Allan L Klein; Sherif F Nagueh; Jordan B Strom Journal: PLoS One Date: 2020-12-22 Impact factor: 3.240
Authors: Ilona Cuijpers; Paolo Carai; Pedro Mendes-Ferreira; Steven J Simmonds; Paul Mulder; Daniela Miranda-Silva; Daria De Giorgio; Peter Pokreisz; Stephane Heymans; Elizabeth A V Jones Journal: Sci Rep Date: 2020-09-24 Impact factor: 4.379