OBJECTIVES: We investigated the frequency of prosthesis-patient mismatch (PPM) after mechanical mitral valve replacement (MVR), its effect on postoperative systolic pulmonary arterial pressure (PAP), and the relationship of indexed effective orifice area (EOA) with systolic PAP and hemodynamic variables of the prosthetic valve. STUDY
DESIGN: The study included 100 patients (27 men, 73 women; mean age 51+/-11 years) with a normally functioning mechanical mitral valve prosthesis. Prosthetic mitral EOA, indexed EOA, and net atrioventricular compliance (Cn) were estimated by Doppler echocardiography. Prosthesis-patient mismatch was defined as an indexed EOA <or=1.2 cm2/m2 and Cn <or=4 ml/mmHg, and pulmonary hypertension (PHT) was defined as systolic PAP >or=40 mmHg.
RESULTS: The frequencies of PPM and postoperative persistent PHT were 33% and 31%, respectively. Postoperative persistent PHT was seen in 79% and 8% in patients with and without PPM, respectively (p<0.001). The frequency of low Cn was significantly higher in patients with PPM (60% vs. 31%; p<0.001). Postoperative systolic PAP was significantly higher in patients with PPM (42.0+/-6.6 mmHg vs. 29.9+/-6.0 mmHg, p<0.0001) and in 41 patients having a low Cn compared to 59 patients having a high Cn (37.2+/-8.8 mmHg vs. 31.6+/-7.4 mmHg, p<0.001). Postoperative systolic PAP was significantly correlated with indexed EOA (r=-0.535, p<0.001) and Cn (r=-0.422, p<0.001), whereas prosthetic valve size was not correlated with systolic PAP (r=0.022, p=0.829) and indexed EOA (r=0.008, p=0.93). In multivariate regression analysis, indexed EOA, age, mean transprosthetic gradient, and Cn were independent factors affecting systolic PAP.
CONCLUSION: Prosthesis-patient mismatch after MVR is associated with persistent PHT. Use of a prosthetic valve that is compatible to the body surface area may significantly reduce the incidence of PPM, and thus the frequency of persistent PHT.

Entities:  

Mesh:

Year:  2009        PMID: 20200452

Source DB:  PubMed          Journal:  Turk Kardiyol Dern Ars        ISSN: 1016-5169


  2 in total

1.  Weight gain potential-a neglected entity during valve replacement.

Authors:  Vijayanand Palanisamy; Karthik Raman; Anjith Prakash Rajakumar; Anbarasu Mohanraj; Jacob Jamesraj; Ejaz Ahmed Sheriff; Valikapthalil Mathew Kurian; Rajan Sethuratnam
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-07-19

2.  Impact of prosthesis-patient mismatch on early and late outcomes after mitral valve replacement: a meta-analysis.

Authors:  Meng-Wei Tan; Yi-Fan Bai; Xiao-Hong Liu; Zhi-Yun Xu; Zhao An; Ye Ma; Li-Bo Zhao; Bai-Ling Li
Journal:  J Geriatr Cardiol       Date:  2020-08       Impact factor: 3.327

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.