Literature DB >> 20199921

Automatic 3-D breath-hold related motion correction of dynamic multislice MRI.

An Elen1, Jeroen Hermans, Javier Ganame, Dirk Loeckx, Jan Bogaert, Frederik Maes, Paul Suetens.   

Abstract

Magnetic resonance (MR) cine images are often used to clinically assess left ventricular cardiac function. In a typical study, multiple 2-D long axis (LA) and short axis (SA) cine images are acquired, each in a different breath-hold. Differences in lung volume during breath-hold and overall patient motion distort spatial alignment of the images thus complicating spatial integration of all image data in three dimensions. We present a fully automatic postprocessing approach to correct these slice misalignments. The approach is based on the constrained optimization of the intensity similarity of intersecting image lines after the automatic definition of a region of interest. It uses all views and all time frames simultaneously. Our method models both in-plane and out-of-plane translations and full 3-D rotations, can be applied retrospectively and does not require a cardiac wall segmentation. The method was validated on both healthy volunteer and patient data with simulated misalignments, as well as on clinical multibreath-hold patient data. For the simulated data, subpixel accuracy could be obtained using translational correction. The possibilities and limitations of rotational correction were investigated and discussed. For the clinical multibreath-hold patient data sets, the median discrepancy between manual SA and LA contours was reduced from 2.83 to 1.33 mm using the proposed correction method. We have also shown the usefulness of the correction method for functional analysis on clinical image data. The same clinical multibreath-hold data sets were resegmented after positional correction, taking newly available complementary information of intersecting slices into account, further reducing the median discrepancy to 0.43 mm. This is due to the integration of the 2-D slice information into 3-D space.

Entities:  

Mesh:

Year:  2010        PMID: 20199921     DOI: 10.1109/TMI.2009.2039145

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  Cardiac MRI segmentation using mutual context information from left and right ventricle.

Authors:  Dwarikanath Mahapatra
Journal:  J Digit Imaging       Date:  2013-10       Impact factor: 4.056

2.  Cardiac image segmentation from cine cardiac MRI using graph cuts and shape priors.

Authors:  Dwarikanath Mahapatra
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

3.  Placement of implantable cardioverter-defibrillators in paediatric and congenital heart defect patients: a pipeline for model generation and simulation prediction of optimal configurations.

Authors:  Lukas J Rantner; Fijoy Vadakkumpadan; Philip J Spevak; Jane E Crosson; Natalia A Trayanova
Journal:  J Physiol       Date:  2013-06-24       Impact factor: 5.182

4.  Improved estimation of the cardiac global function using combined long and short axis MRI images of the heart.

Authors:  Hossam El-Rewaidy; Ahmed S Fahmy
Journal:  Biomed Eng Online       Date:  2016-04-27       Impact factor: 2.819

5.  Cine Cardiac MRI Slice Misalignment Correction Towards Full 3D Left Ventricle Segmentation.

Authors:  Shusil Dangi; Cristian A Linte; Ziv Yaniv
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-12

6.  A geometrical approach for automatic shape restoration of the left ventricle.

Authors:  May-Ling Tan; Yi Su; Chi-Wan Lim; Senthil Kumar Selvaraj; Liang Zhong; Ru-San Tan
Journal:  PLoS One       Date:  2013-07-19       Impact factor: 3.240

7.  Correcting motion in multiplanar cardiac magnetic resonance images.

Authors:  Min Wan; Wei Huang; Jun-Mei Zhang; Xiaodan Zhao; John Carson Allen; Ru San Tan; Xiaofeng Wan; Liang Zhong
Journal:  Biomed Eng Online       Date:  2016-08-08       Impact factor: 2.819

8.  SLIMM: Slice localization integrated MRI monitoring.

Authors:  Yao Sui; Onur Afacan; Ali Gholipour; Simon K Warfield
Journal:  Neuroimage       Date:  2020-08-24       Impact factor: 6.556

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.