Literature DB >> 20199864

Fixation strength of the interference screw in the femoral tunnel: The effect of screw divergence on the coronal plane.

Tadaaki Ninomiya1, Yomei Tachibana, Tsuyoshi Miyajima, Katsuhiko Yamazaki, Hiromi Oda.   

Abstract

Clinical studies to examine the effect of screw divergence have not been applied to the fixation of hamstring grafts. A few previous reports have addressed the correlations between the loss of pullout strength and divergence on hamstring tendon fixation in biomechanical tests. The purpose of this study was to examine the effect of interference screw divergence on the coronal plane when digital flexor tendons were fixed with an interference screw. Twenty fresh porcine hindlimb specimens were chosen. The grafts were fixed using titanium soft tissue interference screws. The hindlimbs were divided into two groups according to the insertion method of the screw. The screw was placed along the graft parallel to the long axis of the femoral tunnel in 10 specimens (parallel placement group), and the others were placed laterally at a 15° divergent angle from the bone tunnel on the coronal plane (divergence group). The cyclic-loading test was loaded for 1500cycles. Five specimens failed because of a pull-out of the tendon in divergence group. The number of specimens that failed before the completion of cycles in the divergence group was significantly greater than that in the parallel placement group. Although the residual displacement after 1500cycles for the divergence group was greater than that for the parallel placement group, no statistically significant difference was found between the groups. This study suggests that the screw placed laterally at a 15° divergent angle on the coronal plane decreases the fixation strength of the digital flexor tendons fixed with an interference screw.
Copyright © 2010 Elsevier B.V. All rights reserved.

Mesh:

Year:  2010        PMID: 20199864     DOI: 10.1016/j.knee.2010.02.003

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  4 in total

1.  Femoral tunnel-interference screw divergence in anterior cruciate ligament reconstruction using bone-patellar tendon-bone graft: A comparison of two techniques.

Authors:  Vivek Pandey; Kiran Acharya; Sharath Rao; Sripathi Rao
Journal:  Indian J Orthop       Date:  2011-05       Impact factor: 1.251

2.  ACL reconstruction with femoral and tibial adjustable versus fixed-loop suspensory fixation: a retrospective cohort study.

Authors:  Sebastian Schützenberger; F Keller; S Grabner; D Kontic; D Schallmayer; M Komjati; C Fialka
Journal:  J Orthop Surg Res       Date:  2022-04-19       Impact factor: 2.677

3.  Categorize the existing clamps used for tensile test of human graft- a systematic review.

Authors:  Denes Farago; Blanka Kozma; Rita Maria Kiss
Journal:  BMC Musculoskelet Disord       Date:  2022-07-25       Impact factor: 2.562

4.  Hyperflexion and Femoral Interference Screw Insertion in ACL Reconstruction.

Authors:  Mark E Steiner; David Wing; Kempland C Walley; Ohan Manoukian; Miguel Perez-Viloria; Stephen Okajima; Ara Nazarian
Journal:  Orthop J Sports Med       Date:  2018-08-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.