Characteristic 8 keV X rays possess radiobiological properties of higher-LET radiation.

Ravi Shridhar1, William Estabrook, Mark Yudelev, Joseph Rakowski, Jay Burmeister, George D Wilson, Michael C Joiner.   

Abstract

Electronic brachytherapy systems are being developed that can deliver X rays of varying energy depending on the material of a secondary target. A copper target produces characteristic 8 keV X rays. Our aim was to determine whether 8 keV X rays might deliver greater biological effectiveness than megavoltage photons. Cells of the U251 human glioma cell line were used to compare the biological effects of 8 keV X rays and (60)Co gamma rays in terms of relative biological effectiveness (RBE), oxygen enhancement ratio (OER), and DNA damage. The RBE at 50% and 10% survival was 2.6 and 1.9, respectively. At 50% survival, the OER for cells treated with 8 keV X rays was 1.6 compared with 3.0 for (60)Co gamma rays. The numbers of H2AX foci per Gy after treatment with 8 keV X rays and (60)Co gamma rays were similar; however, the size of the foci generated at 8 keV was significantly larger, possibly indicating more complex DNA damage. The mean area of H2AX foci generated by 8 keV X rays was 0.785 microm(2) (95% CI: 0.756-0.814) compared with 0.491 microm(2) (95% CI: 0.462-0.520) for (60)Co gamma rays (P < 0.0001). Characteristic 8 keV X rays produce two to three times the biological effectiveness of megavoltage photons, with a radiobiological profile similar to higher-LET radiations.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20199214     DOI: 10.1667/RR1782.1

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  3 in total

1.  Theoretical analysis of the dose dependence of the oxygen enhancement ratio and its relevance for clinical applications.

Authors:  Tatiana Wenzl; Jan J Wilkens
Journal:  Radiat Oncol       Date:  2011-12-15       Impact factor: 3.481

2.  Characterization of relative biological effectiveness for conventional radiation therapy: a comparison of clinical 6 MV X-rays and 137Cs.

Authors:  Michelle Howard; Chris Beltran; Jann Sarkaria; Michael G Herman
Journal:  J Radiat Res       Date:  2017-09-01       Impact factor: 2.724

Review 3.  Biology of high single doses of IORT: RBE, 5 R's, and other biological aspects.

Authors:  Carsten Herskind; Lin Ma; Qi Liu; Bo Zhang; Frank Schneider; Marlon R Veldwijk; Frederik Wenz
Journal:  Radiat Oncol       Date:  2017-01-19       Impact factor: 3.481