Literature DB >> 20198605

Modelling mass analyzer performance with fields determined using the boundary element method.

J Raymond Gibson1, Kenneth G Evans, Stephen Taylor.   

Abstract

Computer modelling is widely used in the design of mass analysers to evaluate proposed designs and determine the effects of manufacturing imperfections. For quadrupole mass filters and ion traps, the models require accurate values of the electric field throughout the regions of the analyser in which ions travel. Most published results using models to predict mass analyser behaviour use electric fields computed with finite element (FE) or finite difference (FD) method. However, the boundary element method (BEM) is capable of achieving the same, or higher, accuracy with both computation times and memory requirements that are at least an order of magnitude less than those required by FE and FD methods. In this paper, electric field evaluation is performed using the BEM formulated in a manner described by previous workers; modifications to their method are described, which lead to higher accuracy field values. Simultaneous equation solution techniques are incorporated, which avoid solutions that are physically not realistic. The performance of linear quadrupole mass spectrometers with hyperbolic, circular and planar section electrodes has been determined using fields computed using these methods and compared with previous results obtained by alternative field computation techniques and with experiment. Behaviour of an ion trap mass spectrometer with circular symmetry has also been investigated. The results demonstrate that in each case using the BEM to determine the fields produces the observed behaviour. Copyright 2010 John Wiley & Sons, Ltd.

Entities:  

Year:  2010        PMID: 20198605     DOI: 10.1002/jms.1720

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  3 in total

1.  A method of computing accurate 3D fields of a quadrupole mass filter and their use for prediction of filter behavior.

Authors:  John R Gibson; Kenneth G Evans; Sarfaraz U Syed; Simon Maher; Stephen Taylor
Journal:  J Am Soc Mass Spectrom       Date:  2012-07-10       Impact factor: 3.109

2.  A quadrupole mass spectrometer for resolution of low mass isotopes.

Authors:  Jeyan Sreekumar; Thomas J Hogan; Stephen Taylor; Phillip Turner; Christopher Knott
Journal:  J Am Soc Mass Spectrom       Date:  2010-04-03       Impact factor: 3.109

3.  Effects of the source gap on transmission efficiency of a quadrupole mass spectrometer.

Authors:  Mariya J Antony Joseph; David G McIntosh; J Raymond Gibson; Stephen Taylor
Journal:  Rapid Commun Mass Spectrom       Date:  2018-05-15       Impact factor: 2.419

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.