Plasma concentrations of salbutamol in the treatment of acute asthma in a pediatric emergency. Could age be a parameter of influence?

Eloni T Rotta1, Sérgio L Amantéa, Pedro E Froehlich, Adriana Becker.   

Abstract

OBJECTIVE: The objective was to determine if the plasma concentrations of salbutamol, obtained during inhalation treatment of infantile acute asthma, are influenced by age range and by the aerosol system used.
METHOD: A randomized clinical trial was conducted in 46 children (1-5 years of age) with a diagnosis of acute asthma crisis, established in an emergency room pediatric service. Twenty-five children received salbutamol using a pressurized metered-dose inhaler with spacer (50 microg/kg), and 21 children received salbutamol by nebulization (150 microg/kg),three times during a 1-h period. At the end of the treatment, one blood sample was drawn and the plasma was stored for later determination of salbutamol concentration (liquid chromatography). Salbutamol plasma concentrations were compared in two age groups (< or =2 years and >2 years of age). The type of device used (pressurized metered-dose inhaler or nebulizer) and the need of hospitalization were also tested. The Mann-Whitney U test was used with the level of significance set at 5% (P < 0.05).
RESULTS: No differences were detected regarding either the aerosol delivery system used or the need for hospitalization in relation to the plasma concentrations of salbutamol. However, higher plasma levels were found in patients >2 years vs patients < or =2 years [median (IQR): 9.40 (6.32-18.22) vs. 4.65 (2.77-10.10) ng/mL], demonstrating a significance difference (P = 0.05).
CONCLUSION: Salbutamol plasma concentrations were influenced by age group of the patients submitted to inhalation therapy, even with doses adjusted for body weight. After correcting for the differences in the biovailabilities of the delivery systems, the concentrations were independent of the aerosol delivery device used.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20195589     DOI: 10.1007/s00228-010-0787-4

Source DB:  PubMed          Journal:  Eur J Clin Pharmacol        ISSN: 0031-6970            Impact factor:   2.953


  20 in total

1.  Comparison of albuterol delivered by a metered dose inhaler with spacer versus a nebulizer in children with mild acute asthma.

Authors:  S Schuh; D W Johnson; D Stephens; S Callahan; P Winders; G J Canny
Journal:  J Pediatr       Date:  1999-07       Impact factor: 4.406

2.  Age dependent systemic exposure to inhaled salbutamol.

Authors:  Klaus Bønnelykke; Jakob Jessing Jespersen; Hans Bisgaard
Journal:  Br J Clin Pharmacol       Date:  2007-03-01       Impact factor: 4.335

Review 3.  Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma.

Authors:  C J Cates; J A Crilly; B H Rowe
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

Review 4.  Pharmacokinetics of inhaled drugs.

Authors:  B J Lipworth
Journal:  Br J Clin Pharmacol       Date:  1996-12       Impact factor: 4.335

Review 5.  Metered-dose inhaler accessory devices in acute asthma: efficacy and comparison with nebulizers: a literature review.

Authors:  I Amirav; M T Newhouse
Journal:  Arch Pediatr Adolesc Med       Date:  1997-09

6.  High-dose albuterol by metered-dose inhaler plus a spacer device versus nebulization in preschool children with recurrent wheezing: A double-blind, randomized equivalence trial.

Authors:  D Ploin; F R Chapuis; D Stamm; J Robert; L David; P G Chatelain; G Dutau; D Floret
Journal:  Pediatrics       Date:  2000-08       Impact factor: 7.124

7.  Determination of plasma salbutamol concentrations after nebulization in a pediatric emergency department.

Authors:  Eloni T Rotta; Sérgio L Amantéa; Pedro E Froehlich; Adriana Becker
Journal:  J Pediatr (Rio J)       Date:  2007-08-30       Impact factor: 2.197

8.  Salbutamol via metered-dose inhaler with spacer versus nebulization for acute treatment of pediatric asthma in the emergency department.

Authors:  Javier Benito-Fernández; María González-Balenciaga; Susana Capapé-Zache; Miguel A Vázquez-Ronco; Santiago Mintegi-Raso
Journal:  Pediatr Emerg Care       Date:  2004-10       Impact factor: 1.454

9.  Efficacy of albuterol administered by nebulizer versus spacer device in children with acute asthma.

Authors:  E Kerem; H Levison; S Schuh; H O'Brodovich; J Reisman; L Bentur; G J Canny
Journal:  J Pediatr       Date:  1993-08       Impact factor: 4.406

10.  Efficacy of bronchodilators administered by nebulizers versus spacer devices in infants with acute wheezing.

Authors:  R M Closa; J M Ceballos; A Gómez-Papí; A S Galiana; C Gutiérrez; C Martí-Henneber
Journal:  Pediatr Pulmonol       Date:  1998-11
View more
  1 in total

1.  Population Pharmacokinetics of Intravenous Salbutamol in Children with Refractory Status Asthmaticus.

Authors:  Nienke J Vet; Brenda C M de Winter; Muriel Koninckx; Shelley A Boeschoten; Annemie L M Boehmer; Jacintha T Verhallen; Frans B Plötz; Anja A Vaessen-Verberne; Bart C H van der Nagel; Catherijne A J Knibbe; Corinne M P Buysse; Saskia N de Wildt; Birgit C P Koch; Matthijs de Hoog
Journal:  Clin Pharmacokinet       Date:  2020-02       Impact factor: 6.447

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.