BACKGROUND: The best method for performing atrial fibrillation (AF) ablation is still under debate. The importance of using a circular mapping (CM) catheter for assessing isolation of the pulmonary vein (PV) antrum on the outcome of the procedure has not been clearly established. OBJECTIVE: The purpose of this study was to evaluate whether use of a CM catheter improves the arrhythmia-free proportion after circumferential pulmonary vein ablation (CPVA). METHODS: A series of 146 consecutive patients (83% males, age 53 +/- 10 years, 53% paroxysmal AF) were randomized to two ablation strategies. In both groups, ipsilateral PV encirclement was performed until disappearance or dissociation of the local electrogram within the surrounded area. In the first group, only the radiofrequency catheter was used to both map and ablate (CPVA group, n = 73). In the other group, a CM catheter was added to assess the electrical activity of the PV antrum (CPVA-CM group, n = 73). An ablation line along the left atrial roof was also created in all patients. RESULTS:Procedural and fluoroscopic times were longer in the CPVA-CM group (P <.05). Severe procedure-related complications occurred in 1 (1.4%) patient in the CPVA group and in 3 (4.1%) patients in the CPVA-CM group (P = .317). After mean follow-up of 9 +/- 3 months, 31 (42.5%) patients in the CPVA group and 47 (64.4%) patients in the CPVA-CM group were arrhythmia-free without antiarrhythmic medication (P = .008). CONCLUSION: Use of a CM catheter to ensure isolation of the PV antrum improved the success of CPVA but increased some procedural requirements. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
RCT Entities:
BACKGROUND: The best method for performing atrial fibrillation (AF) ablation is still under debate. The importance of using a circular mapping (CM) catheter for assessing isolation of the pulmonary vein (PV) antrum on the outcome of the procedure has not been clearly established. OBJECTIVE: The purpose of this study was to evaluate whether use of a CM catheter improves the arrhythmia-free proportion after circumferential pulmonary vein ablation (CPVA). METHODS: A series of 146 consecutive patients (83% males, age 53 +/- 10 years, 53% paroxysmal AF) were randomized to two ablation strategies. In both groups, ipsilateral PV encirclement was performed until disappearance or dissociation of the local electrogram within the surrounded area. In the first group, only the radiofrequency catheter was used to both map and ablate (CPVA group, n = 73). In the other group, a CM catheter was added to assess the electrical activity of the PV antrum (CPVA-CM group, n = 73). An ablation line along the left atrial roof was also created in all patients. RESULTS: Procedural and fluoroscopic times were longer in the CPVA-CM group (P <.05). Severe procedure-related complications occurred in 1 (1.4%) patient in the CPVA group and in 3 (4.1%) patients in the CPVA-CM group (P = .317). After mean follow-up of 9 +/- 3 months, 31 (42.5%) patients in the CPVA group and 47 (64.4%) patients in the CPVA-CM group were arrhythmia-free without antiarrhythmic medication (P = .008). CONCLUSION: Use of a CM catheter to ensure isolation of the PV antrum improved the success of CPVA but increased some procedural requirements. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Authors: Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber Journal: J Interv Card Electrophysiol Date: 2012-03 Impact factor: 1.900
Authors: Dirk Vollmann; Lars Lüthje; Joachim Seegers; Christian Sohns; Samuel Sossalla; Jan Sohns; Christian Röver; Gerd Hasenfuß; Markus Zabel Journal: J Interv Card Electrophysiol Date: 2014-06-04 Impact factor: 1.900