Dirk Wildemeersch1, A Andrade. 1. Outpatient Gynaecological Clinic and IUD Training Center, Ghent, Belgium. d.wildemeersch@skynet.be
Abstract
OBJECTIVE: Review the clinical experience with the frameless FibroPlant levonorgestrel intrauterine system (FP-LNG-IUS). STUDY DESIGN: An open, prospective non-comparative contraceptive 5-year study; a 1-year MBL study in women with heavy menstrual bleeding (HMB), using a PBAC and a 2-year MBL study in women with HMB and with normal menstruation using the quantitative alkaline hematin method. A literature review on perforation rate with the frameless GyneFix and FibroPlant. RESULTS: 304 insertions were performed with the FP-LNG-IUS. The total observation period was 11,299 woman-months. Only one pregnancy occurred. There were two expulsions and two uterine perforations at insertion during the first year. In the first 1-year MBL study, the median MBL decreased by more than 90%. In the second 2-year MBL study, MBL reduced drastically and 80% had amenorrhoea after 24 months. The ferritin values increased significantly. On a total of approximately 17,000 insertions, the perforation rate was between 1.2 and 2.0/1000 insertions. CONCLUSION: The frameless FP-LNG-IUS is an effective and well-tolerated long-acting reversible contraceptive and is also highly effective for the treatment of HMB. The perforation rate is similar to traditional copper and levonorgestrel-releasing intrauterine devices and systems. Strict adherence to the manufacturer's insertion instructions is recommended.
OBJECTIVE: Review the clinical experience with the frameless FibroPlant levonorgestrel intrauterine system (FP-LNG-IUS). STUDY DESIGN: An open, prospective non-comparative contraceptive 5-year study; a 1-year MBL study in women with heavy menstrual bleeding (HMB), using a PBAC and a 2-year MBL study in women with HMB and with normal menstruation using the quantitative alkaline hematin method. A literature review on perforation rate with the frameless GyneFix and FibroPlant. RESULTS: 304 insertions were performed with the FP-LNG-IUS. The total observation period was 11,299 woman-months. Only one pregnancy occurred. There were two expulsions and two uterine perforations at insertion during the first year. In the first 1-year MBL study, the median MBL decreased by more than 90%. In the second 2-year MBL study, MBL reduced drastically and 80% had amenorrhoea after 24 months. The ferritin values increased significantly. On a total of approximately 17,000 insertions, the perforation rate was between 1.2 and 2.0/1000 insertions. CONCLUSION: The frameless FP-LNG-IUS is an effective and well-tolerated long-acting reversible contraceptive and is also highly effective for the treatment of HMB. The perforation rate is similar to traditional copper and levonorgestrel-releasing intrauterine devices and systems. Strict adherence to the manufacturer's insertion instructions is recommended.