Literature DB >> 20190705

Late onset postoperative pulmonary fistula following a pulmonary segmentectomy using electrocautery or a harmonic scalpel.

Keigo Takagi1, Yoshinobu Hata, Shuichi Sasamoto, Kazuyoshi Tamaki, Kazuhiko Fukumori, Hajime Otsuka, Chiyoko Hasegawa, Kazutoshi Shibuya.   

Abstract

PURPOSE: The purpose of this study is to retrospectively examine the postoperative pulmonary fistula as a complication after the use of either electrocautery or a harmonic scalpel without stapling devices. PATIENTS AND METHODS: The subjects of this study consisted of 28 patients who received a segmentectomy for a pulmonary malignant tumor, 25 cases of lung cancer and 3 of metastatic lung tumor. The electrocautery was used in 17 patients (EC group) and the harmonic scalpel in 11 (HS group). The levels of postoperative air leakage and postoperative complications were examined among the two groups retrospectively. The histological findings of the cut surface of the segmentectomy by electrocautery and harmonic scalpel were also examined.
RESULTS: Hemostasis and air leakage both were well controlled during the operation, and the postoperative drainage period was short. No major postoperative complications occurred, and all patients began walking in the early postoperative days. However, 1 to 3 postoperative months after discharge, 8 patients showed late onset of a pulmonary fistula, 3 of the 17 (18%) in the EC group and 5 of the 11 (45%) in the HS group. The histological findings of the cut surface of the segmentectomy showed that most of the layer of coagulation necrosis by the harmonic scalpel measured 2 mm thick, and it was denser than that cut from electrocautery. The lumen of the bronchus markedly decreased in size, but it remained, as it also did under the effects of electrocautery.
CONCLUSIONS: In the months following the operation, the incidence of the late onset of a pulmonary fistula was higher when the harmonic scalpel was used. It was believed that the small bronchial stump could not tolerate the airway pressure because the thick coagulation necrosis delayed healing of the postoperative wound. It was necessary to ligate the stump of a small bronchus, even though the stump had been temporally closed by coagulation necrosis with the electrocautery or harmonic scalpel during the operation.

Entities:  

Mesh:

Year:  2010        PMID: 20190705

Source DB:  PubMed          Journal:  Ann Thorac Cardiovasc Surg        ISSN: 1341-1098            Impact factor:   1.520


  5 in total

1.  Management of the inter-segmental plane using the "Combined Dimensional Reduction Method" is safe and viable in uniport video-assisted thoracoscopic pulmonary segmentectomy.

Authors:  Bin Zheng; Guobing Xu; Xiayu Fu; Weidong Wu; Mingqiang Liang; Taidui Zeng; Shuliang Zhang; Yong Zhu; Wei Zheng; Chun Chen; Benoît Bédat; Scott J Swanson; Terumoto Koike; Hisashi Iwata; Benedetta Bedetti; Masaaki Sato
Journal:  Transl Lung Cancer Res       Date:  2019-10

2.  Focus harmonic scalpel compared to conventional haemostasis in open total thyroidectomy: a prospective randomized trial.

Authors:  Emanuele Ferri; Enrico Armato; Giacomo Spinato; Roberto Spinato
Journal:  Int J Otolaryngol       Date:  2011-09-29

3.  Review of Approaches to Developing Intersegmental Plane during Segmentectomy.

Authors:  Xingshi Chen; Zhengyuan Zhang; Ning Xu; Dongchun Ma; Hecheng Li
Journal:  Thorac Cardiovasc Surg       Date:  2021-04-16       Impact factor: 1.756

4.  Impact of pulmonary rehabilitation on postoperative complications in patients with lung cancer and chronic obstructive pulmonary disease.

Authors:  Hajime Saito; Kazutoshi Hatakeyama; Hayato Konno; Toshiki Matsunaga; Yoichi Shimada; Yoshihiro Minamiya
Journal:  Thorac Cancer       Date:  2017-07-11       Impact factor: 3.500

Review 5.  Late-onset bronchopleural fistula after lobectomy and adjuvant chemotherapy for lung cancer: A case report and review of the literature.

Authors:  Chu Zhang; Yong Pan; Rui-Mei Zhang; Wen-Bin Wu; Dong Liu; Miao Zhang
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.