Literature DB >> 20189695

A three-dimensional parameterized and visually kinematic simulation module for the theoretical range of motion of total hip arthroplasty.

Wen-Ting Ji1, Kai Tao, Cheng-Tao Wang.   

Abstract

BACKGROUND: Proper option and optimal alignment of implants are major factors in obtaining the desired range of motion of total hip arthroplasty. It would be very useful if a tool is available to assist clinicians to preoperatively determine proper implants and their optimal intraoperative alignment for individual patient.
METHODS: Based on the secondary development function of ADAMS/VIEW, a three-dimensional parameterized module was developed to simulate six motions of implants for total hip arthroplasty. Total eight parameters (stem abduction, acetabular size, head size, general head-neck ratio, stem-neck angle, acetabular anteversion, acetabular inclination and femoral antetorsion) were included and three definitions of acetabular orientations (operative, radiographic and anatomical) were available. Any initial position of implants and simulation precision could be defined on the demand.
FINDINGS: After entering these eight parameters, a special model of total hip arthroplasty would be constructed. Single or combined motion until the prosthetic impingement could be simulated visually and the corresponding maximal rotation angle would be quantified.
INTERPRETATION: Clinical factors, such as patients with severe deformity of hip joint or a large range of motion demand, should be considered during total hip arthroplasty. This module can provide references for clinicians on proper option and intraoperative implantation of components, and be suitable for postoperative evaluation. Furthermore, it is a tool to investigate the "safe-zones" of total hip arthroplasty and also can be employed for the design of new implant system. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20189695     DOI: 10.1016/j.clinbiomech.2010.01.012

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  2 in total

1.  Motion performance and impingement risk of total hip arthroplasty with a simulation module.

Authors:  Hai Zhou; Cheng-tao Wang; Wen-ting Ji; Xiang-sen Zeng; Shu Fang; Dong-mei Wang
Journal:  J Zhejiang Univ Sci B       Date:  2013-09       Impact factor: 3.066

2.  Influencing factors for the increased stem version compared to the native femur in cementless total hip arthroplasty.

Authors:  Masanobu Hirata; Yasuharu Nakashima; Takashi Itokawa; Masanobu Ohishi; Taishi Sato; Mio Akiyama; Daisuke Hara; Yukihide Iwamoto
Journal:  Int Orthop       Date:  2014-02-07       Impact factor: 3.075

  2 in total