An environmentally friendly analytical procedure with high sensitivity for determination of carbaryl pesticide in natural waters was developed. The flow system was designed with solenoid micro-pumps in order to improve mixing conditions and minimize reagent consumption as well as waste generation. A long pathlength (100 cm) flow cell based on a liquid core waveguide (LCW) was employed to increase the sensitivity in detection of the indophenol formed from the reaction between carbaryl and p-aminophenol (PAP). A clean-up step based on cloud-point extraction was explored to remove the interfering organic matter, avoiding the use of toxic organic solvents. A linear response was observed within the range 5-200 microg L(-1) and the detection limit, coefficient of variation and sampling rate were estimated as 1.7 microg L(-1) (99.7% confidence level), 0.7% (n=20) and 55 determinations per hour, respectively. The reagents consumption was 1.9 microg of PAP and 5.7 microg of potassium metaperiodate, with volume of 2.6 mL of effluent per determination. The proposed procedure was selective for the determination of carbaryl, without interference from other carbamate pesticides. Recoveries within 84% and 104% were estimated for carbaryl spiked to water samples and the results obtained were also in agreement with those found by a batch spectrophotometric procedure at the 95% confidence level. The waste of the analytical procedure was treated with potassium persulphate and ultraviolet irradiation, yielding a colorless residue and a decrease of 94% of total organic carbon. In addition, the residue after treatment was not toxic for Vibrio fischeri bacteria. (c) 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20188927     DOI: 10.1016/j.talanta.2009.12.005

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  An environmental friendly procedure for photometric determination of hypochlorite in tap water employing a miniaturized multicommuted flow analysis setup.

Authors:  Sivanildo S Borges; Boaventura F Reis
Journal:  J Autom Methods Manag Chem       Date:  2011-05-05

2.  Magnetic Solid-Phase Extraction of Carbamate Pesticides Using Magnetic Metal-Organic Frameworks Derived from Benzoate Ligands, Followed by Digital Image Colorimetric Screening and High-Performance Liquid Chromatography Analysis.

Authors:  Jirasak Gamonchuang; Yanawath Santaladchaiyakit; Rodjana Burakham
Journal:  ACS Omega       Date:  2022-03-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.