Literature DB >> 20188880

Flexible thick-film glucose biosensor: influence of mechanical bending on the performance.

Min-Chieh Chuang1, Yang-Li Yang, Ta-Feng Tseng, Tzuyang Chou, Shyh-Liang Lou, Joseph Wang.   

Abstract

The influence of the bending-induced mechanical stress of flexible Nafion/GOx/carbon screen-printed electrodes (SPEs) upon the performance of such glucose biosensors has been examined. Surprisingly, such flexible enzyme/polymer-SPEs operate well following a severe bending-induced mechanical stress (including a 180 degrees pinch), and actually display a substantial sensitivity enhancement following their mechanical bending. The bending-induced sensitivity enhancement is observed only for the amperometric detection of the glucose substrate but not for measurements of hydrogen peroxide, catechol or ferrocyanide at coated or bare SPEs. These (and additional) data indicate that the bending effect is associated primarily with changes in the biocatalytic activity. Such sensitivity enhancement is more pronounced at elevated glucose levels, reflecting the bending-induced changes in the biocatalytic reaction. Factors affecting the bending-induced changes in the performance are examined. While our data clearly indicate that flexible enzyme/polymer-SPEs can tolerate a severe mechanical stress and hold promise as wearable glucose biosensors, delivering the sample to the active sensor surface remains the major challenge for such continuous health monitoring. (c) 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20188880     DOI: 10.1016/j.talanta.2009.11.029

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A novel device for detecting anaerobic threshold using sweat lactate during exercise.

Authors:  Yuta Seki; Daisuke Nakashima; Yasuyuki Shiraishi; Toshinobu Ryuzaki; Hidehiko Ikura; Kotaro Miura; Masato Suzuki; Takatomo Watanabe; Takeo Nagura; Morio Matsumato; Masaya Nakamura; Kazuki Sato; Keiichi Fukuda; Yoshinori Katsumata
Journal:  Sci Rep       Date:  2021-03-02       Impact factor: 4.379

2.  A wearable chemical-electrophysiological hybrid biosensing system for real-time health and fitness monitoring.

Authors:  Somayeh Imani; Amay J Bandodkar; A M Vinu Mohan; Rajan Kumar; Shengfei Yu; Joseph Wang; Patrick P Mercier
Journal:  Nat Commun       Date:  2016-05-23       Impact factor: 14.919

3.  Glove-based sensors for multimodal monitoring of natural sweat.

Authors:  Mallika Bariya; Lu Li; Rahul Ghattamaneni; Christine Heera Ahn; Hnin Yin Yin Nyein; Li-Chia Tai; Ali Javey
Journal:  Sci Adv       Date:  2020-08-28       Impact factor: 14.136

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.