Literature DB >> 20187182

Effect of blood flow on double inversion recovery vessel wall MRI of the peripheral arteries: quantitation with T2 mapping and comparison with flow-insensitive T2-prepared inversion recovery imaging.

Ryan Brown1, Thanh D Nguyen, Pascal Spincemaille, Matthew D Cham, Grace Choi, Priscilla A Winchester, Martin R Prince, Yi Wang.   

Abstract

Blood suppression in the lower extremities using flow-reliant methods such as double inversion recovery may be problematic due to slow blood flow. T(2) mapping using fast spin echo (FSE) acquisition was utilized to quantitate the effectiveness of double inversion recovery blood suppression in 13 subjects and showed that 25 +/- 12% of perceived vessel wall pixels in the popliteal arteries contained artifactual blood signal. To overcome this problem, a flow-insensitive T(2)-prepared inversion recovery sequence was implemented and optimal timing parameters were calculated for FSE acquisition. Black blood vessel wall imaging of the popliteal and femoral arteries was performed using two-dimensional T(2)-prepared inversion recovery-FSE in the same 13 subjects. Comparison with two-dimensional double inversion recovery-FSE showed that T(2)-prepared inversion recovery-FSE reduced wall-mimicking blood artifacts that inflated double inversion recovery-FSE vessel wall area measurements in the popliteal artery. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20187182      PMCID: PMC2921169          DOI: 10.1002/mrm.22227

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  39 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  T1-insensitive flow suppression using quadruple inversion-recovery.

Authors:  Vasily L Yarnykh; Chun Yuan
Journal:  Magn Reson Med       Date:  2002-11       Impact factor: 4.668

3.  Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)-algorithm: principles and applications to hyperecho and TRAPS sequences.

Authors:  Juergen Hennig; Matthias Weigel; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences.

Authors:  Simon J P Meara; Gareth J Barker
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

5.  Relaxation-selective magnetization preparation based on T1 and T2.

Authors:  Mark D Does
Journal:  J Magn Reson       Date:  2005-02       Impact factor: 2.229

6.  Fast selective black blood MR imaging.

Authors:  R R Edelman; D Chien; D Kim
Journal:  Radiology       Date:  1991-12       Impact factor: 11.105

7.  Relation of aortic wall thickness and distensibility to cardiovascular risk factors (from the Multi-Ethnic Study of Atherosclerosis [MESA]).

Authors:  Ashkan A Malayeri; Shunsuke Natori; Hossein Bahrami; Alain G Bertoni; Richard Kronmal; João A C Lima; David A Bluemke
Journal:  Am J Cardiol       Date:  2008-05-24       Impact factor: 2.778

8.  Blood flow measurements in the aorta and major arteries with MR velocity mapping.

Authors:  H G Bogren; M H Buonocore
Journal:  J Magn Reson Imaging       Date:  1994 Mar-Apr       Impact factor: 4.813

9.  Effects of percutaneous transluminal angioplasty and endovascular brachytherapy on vascular remodeling of human femoropopliteal artery by noninvasive magnetic resonance imaging.

Authors:  Rolf Wyttenbach; Augusto Gallino; Mario Alerci; Felix Mahler; Luca Cozzi; Marcello Di Valentino; Juan J Badimon; Valentin Fuster; Roberto Corti
Journal:  Circulation       Date:  2004-08-23       Impact factor: 29.690

10.  Magnetic resonance imaging of carotid atherosclerosis: plaque analysis.

Authors:  William Kerwin; Dongxiang Xu; Fei Liu; Tobias Saam; Hunter Underhill; Norihide Takaya; Baocheng Chu; Thomas Hatsukami; Chun Yuan
Journal:  Top Magn Reson Imaging       Date:  2007-10
View more
  6 in total

1.  Three-dimensional flow-independent balanced steady-state free precession vessel wall MRI of the popliteal artery: preliminary experience and comparison with flow-dependent black-blood techniques.

Authors:  Keigo Kawaji; Thanh D Nguyen; Zhitong Zou; Beatriu Reig; Priscilla A Winchester; Andrew Shih; Pascal Spincemaille; Martin R Prince; Yi Wang
Journal:  J Magn Reson Imaging       Date:  2011-07-18       Impact factor: 4.813

2.  Simultaneous bilateral magnetic resonance imaging of the femoral arteries in peripheral arterial disease patients.

Authors:  Ryan Brown; Christof Karmonik; Gerd Brunner; Alan Lumsden; Christie Ballantyne; Shawna Johnson; Yi Wang; Joel Morrisett
Journal:  J Magn Reson Imaging       Date:  2011-05-19       Impact factor: 4.813

3.  Impact of T2 decay on carotid artery wall thickness measurements.

Authors:  Ye Qiao; David A Steinman; Maryam Etesami; Alex Martinez-Marquese; Edward G Lakatta; Bruce A Wasserman
Journal:  J Magn Reson Imaging       Date:  2012-11-21       Impact factor: 4.813

4.  Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging.

Authors:  Anthony G Christodoulou; Jaime L Shaw; Christopher Nguyen; Qi Yang; Yibin Xie; Nan Wang; Debiao Li
Journal:  Nat Biomed Eng       Date:  2018-04-09       Impact factor: 25.671

Review 5.  Vessel wall MR imaging in neuroradiology.

Authors:  Yasutaka Fushimi; Kazumichi Yoshida; Masakazu Okawa; Takakuni Maki; Satoshi Nakajima; Akihiko Sakata; Sachi Okuchi; Takuya Hinoda; Mitsunori Kanagaki; Yuji Nakamoto
Journal:  Radiol Med       Date:  2022-07-30       Impact factor: 6.313

6.  Three-dimensional whole-brain simultaneous T1, T2, and T1ρ quantification using MR Multitasking: Method and initial clinical experience in tissue characterization of multiple sclerosis.

Authors:  Sen Ma; Nan Wang; Zhaoyang Fan; Marwa Kaisey; Nancy L Sicotte; Anthony G Christodoulou; Debiao Li
Journal:  Magn Reson Med       Date:  2020-10-26       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.