Literature DB >> 20187079

Mass spectrometric characterization of tamoxifene metabolites in human urine utilizing different scan parameters on liquid chromatography/tandem mass spectrometry.

Monica Mazzarino1, Xavier de la Torre, Roberto Di Santo, Ilaria Fiacco, Federica Rosi, Francesco Botrè.   

Abstract

Different liquid chromatographic/tandem mass spectrometric (LC/MS/MS) scanning techniques were considered for the characterization of tamoxifene metabolites in human urine for anti-doping purpose. Five different LC/MS/MS scanning methods based on precursor ion scan (precursor ion scan of m/z 166, 152 and 129) and neutral loss scan (neutral loss of 72 Da and 58 Da) in positive ion mode were assessed to recognize common ions or common losses of tamoxifene metabolites. The applicability of these methods was checked first by infusion and then by the injection of solution of a mixture of reference standards of four tamoxifene metabolites available in our laboratory. The data obtained by the analyses of the mixture of the reference standards showed that the five methods used exhibited satisfactory results for all tamoxifene metabolites considered at a concentration level of 100 ng/mL, whereas the analysis of blank urine samples spiked with the same tamoxifene metabolites at the same concentration showed that the neutral loss scan of 58 Da lacked sufficient specificity and sensitivity. The limit of detection in urine of the compounds studied was in the concentration range 10-100 ng/mL, depending on the compound structure and on the selected product ion. The suitability of these approaches was checked by the analysis of urine samples collected after the administration of a single dose of 20 mg of tamoxifene. Six metabolites were detected: 4-hydroxytamoxifene, 3,4-dihydroxytamoxifene, 3-hydroxy-4-methoxytamoxifene, N-demethyl-4-hydroxytamoxifene, tamoxifene-N-oxide and N-demethyl-3-hydroxy-4-methoxytamoxifene, which is in conformity to our previous work using a time-of-flight (TOF) mass spectrometer in full scan acquisition mode. Copyright (c) 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20187079     DOI: 10.1002/rcm.4432

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

1.  Smart coumarin-tagged imprinted polymers for the rapid detection of tamoxifen.

Authors:  Judith V Ray; Fosca Mirata; Celine Pérollier; Michel Arotcarena; Sami Bayoudh; Marina Resmini
Journal:  Anal Bioanal Chem       Date:  2016-02-09       Impact factor: 4.142

2.  Non-allowed Pharmacologically Active Substances in Physical and Sexual Performance Enhancing Products.

Authors:  Manuela Pellegrinia; Maria Concetta Rotolo; Francesco Paolo Busardò; Roberta Pacifici; Simona Pichini
Journal:  Curr Neuropharmacol       Date:  2017       Impact factor: 7.363

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.