Literature DB >> 20185490

Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation.

Rypko P Beukema1, Willem P Beukema, Jaap Jan J Smit, Anand R Ramdat Misier, Peter Paul H M Delnoij, Hein Wellens, Arif Elvan.   

Abstract

AIM: A novel multi-electrode pulmonary vein ablation catheter (PVAC) combining circular mapping and duty-cycled multi-electrode radiofrequency (RF) energy delivery has been developed to map and isolate the pulmonary veins (PVs). The aim of this study was to assess the efficacy of multi-electrode RF ablation using the PVAC device. METHODS AND
RESULTS: A total of 102 consecutive patients, age 57.9 +/- 9.6 years, with paroxysmal or persistent drug refractory atrial fibrillation (AF) were referred for ablation. All patients had documented AF episodes with an AF duration of 9.3 +/- 7.5 years (range 1.5-25). The mean total procedure time was 139.30 +/- 37.72 (median 135, range 115-172). The mean fluoroscopy time required for PVAC ablation was 17 +/- 12 min (median 16, range 12-33) and the total fluoroscopy time was 32.1 +/- 11.3 min (median 29, range 25-39). The mean multi-electrode RF ablation time required to achieve complete PV isolation was 31 +/- 6.7 min (range 16-51). In eight patients with persistent AF, additional ablations were performed to defragment septal and posterior part of the left atrium. In five patients additional RF ablations using conventional catheters were necessary. After multi-electrode duty-cycled RF ablation, 62 of 102 (60.8%) patients were in sustained sinus rhythm without anti-arrhythmic drugs. The mean follow-up duration was 12.2 +/- 3.9 months (range 6-15).
CONCLUSION: This novel multi-electrode ablation technique can be used for PV isolation and left atrium ablation with a relatively low medium-term success rate after the first ablation of approximately 61%. Larger studies with longer follow-up are required to evaluate the efficacy and whether multi-electrode RF ablation is associated with a different complication rate compared with standard PV isolation.

Entities:  

Mesh:

Year:  2010        PMID: 20185490     DOI: 10.1093/europace/euq023

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  18 in total

1.  Phased multipolar radiofrequency pulmonary vein isolation is as effective and safe as conventional irrigated point-to-point ablation. A prospective randomised 1-year implantable cardiac monitoring device follow-up trial.

Authors:  S J Podd; A N Sulke; C Sugihara; S S Furniss
Journal:  J Interv Card Electrophysiol       Date:  2015-08-27       Impact factor: 1.900

Review 2.  Multi-Electrode Ablation Catheters for AF Ablation: Effective Reality or Elegant Experiment?

Authors:  Lucas Boersma
Journal:  J Atr Fibrillation       Date:  2012-06-15

Review 3.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

Review 4.  Comparison of the Efficacy of PVAC® and nMARQ for paroxysmal atrial fibrillation.

Authors:  Avishag Laish-Farkash; Mahmoud Suleiman
Journal:  J Atr Fibrillation       Date:  2017-04-30

Review 5.  Durable Pulmonary Vein Isolation: The Holy Grail of Atrial Fibrillation Ablation.

Authors:  Duy Thai Nguyen; William H Sauer
Journal:  J Atr Fibrillation       Date:  2013-10-31

Review 6.  Silent Cerebral Embolism during Atrial Fibrillation Ablation:Pathophysiology, Prevention and Management.

Authors:  Matteo Anselmino; Mario Matta; Elisabetta Toso; Federico Ferraris; Davide Castagno; Marco Scaglione; Federico Cesarani; Riccardo Faletti; Fiorenzo Gaita
Journal:  J Atr Fibrillation       Date:  2013-08-31

7.  Pulmonary vein stenosis after pulmonary vein isolation using duty-cycled unipolar/bipolar radiofrequency ablation guided by intracardiac echocardiography.

Authors:  Stefan Asbach; Fabienne Schluermann; Luca Trolese; Mathias Langer; Christoph Bode; Tobias Krauss
Journal:  J Interv Card Electrophysiol       Date:  2015-06-17       Impact factor: 1.900

8.  Pulmonary vein re-isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation: safety and efficacy of a primary 2:1 bipolar/unipolar ablation mode.

Authors:  Marcus Wieczorek; Reinhard Hoeltgen; Shahram Tajtaraghi; Wolfgang Lawrenz; Michael Lukat
Journal:  J Interv Card Electrophysiol       Date:  2012-10-25       Impact factor: 1.900

Review 9.  One-Shot Ablation For PV Isolation.

Authors:  Miguel Nobre Menezes; Nuno Cortez-Dias; Luís Carpinteiro; João de Sousa
Journal:  J Atr Fibrillation       Date:  2014-08-31

Review 10.  Phased RF Ablation: Results and Concerns.

Authors:  Alexandra Kiss; Gábor Sándorfi; Edina Nagy-Baló; Mihran Martirosyan; Zoltan Csanadi
Journal:  J Atr Fibrillation       Date:  2015-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.