Literature DB >> 20185482

Intracardiac impedance monitors stroke volume in resynchronization therapy patients.

Mario Bocchiardo1, Dorothee Meyer zu Vilsendorf, Carmelo Militello, Michael Lippert, Gerald Czygan, Fiorenzo Gaita, Patrick Schauerte, Christoph Stellbrink.   

Abstract

AIMS: Monitoring of haemodynamic parameters or surrogate parameters of the left ventricle is especially important for patients under cardiac resynchronization therapy (CRT). Intracardiac impedance reflects left ventricular (LV) volume changes well in animal models. Since it is unknown whether this also holds in humans with heart failure (HF), we examined the correlation of LV intracardiac impedance with haemodynamic parameters in CRT patients for different positions of the LV lead. METHODS AND
RESULTS: In 14 HF patients with non-ischaemic cardiomyopathy (four female, age 70 +/- 6 years, NYHA 2.9 +/- 0.3, EF 26 +/- 6%), one or two suitable implantation sites for the LV lead were selected. Following atrial, right ventricular, and LV catheter positioning, a micro-manometer catheter was placed in the ascending aorta. Surface ECG, impedance, and aortic pressure were recorded during graded overdrive bi-ventricular pacing in DDD mode. The correlation between impedance and stroke volume (SV) or pulse pressure (PP) changes was compared for different LV lead positions. In total, 20 overdrive pacing tests were performed at six different LV lead positions. Strong correlations were found between stroke impedance (SZ) and SV (R = 0.82 +/- 0.16) as well as between SZ and PP (R = 0.81 +/- 0.16) without significant influence of LV lead position.
CONCLUSION: In HF patients, a strong correlation between changes in intracardiac impedance and LV SV was found. Typical LV lead implant positions have been tested and all appear to be suitable for this method of LV volume monitoring.

Entities:  

Mesh:

Year:  2010        PMID: 20185482     DOI: 10.1093/europace/euq045

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  4 in total

1.  Remote monitoring of heart failure patients using implantable cardiac pacing devices and external sensors: results of the Insight-HF study.

Authors:  Ann Lieback; Jochen Proff; Kai Wessel; Eckart Fleck; Stephan Götze
Journal:  Clin Res Cardiol       Date:  2011-10-05       Impact factor: 5.460

2.  Hemodynamic monitoring by intracardiac impedance measured by cardiac resynchronization defibrillators: Evaluation in a controlled clinical setting (BIO.Detect HF II study).

Authors:  Peter-Paul Henri Marie Delnoy; Klaus-Jürgen Gutleben; Niels Eske Bruun; Sebastian K G Maier; Hanno Oswald; Christoph Stellbrink; Jens Brock Johansen; Stefan Paule; Peter Søgaard
Journal:  Indian Pacing Electrophysiol J       Date:  2021-04-15

3.  Intracardiac impedance to track cardiac volume status during cardiac resynchronization therapy - The quest for a heart failure sensor.

Authors:  Niraj Varma
Journal:  Indian Pacing Electrophysiol J       Date:  2021 Jul-Aug

4.  Impact of acute changes of left ventricular contractility on the transvalvular impedance: validation study by pressure-volume loop analysis in healthy pigs.

Authors:  Vincenzo Lionetti; Simone Lorenzo Romano; Giacomo Bianchi; Fabio Bernini; Anar Dushpanova; Giuseppe Mascia; Martina Nesti; Franco Di Gregorio; Alberto Barbetta; Luigi Padeletti
Journal:  PLoS One       Date:  2013-11-19       Impact factor: 3.240

  4 in total