Diagnostic yield of ink-jet prints from digital radiographs for the assessment of approximal carious lesions: ROC-analysis.

Ralf K W Schulze1, Stefanie Grimm, Dirk Schulze, Kai Voss, Hans-Peter Keller, Matthias Wedel.   

Abstract

AIMS: To investigate the diagnostic quality of different quality, individually calibrated ink-jet printers for the very challenging dental radiographic task of approximal carious lesion detection.
MATERIALS AND METHODS: A test-pattern evaluating resolution, contrast and homogeneity of the ink-jet prints was developed. 50 standardized dental radiographs each showing two neighbouring teeth in natural contact were printed on glossy paper with calibrated, randomly selected ink-jet printers (Canon S520 and iP4500, Epson Stylus Photo R2400). Printing size equalled the viewing size on a 17″ cathode-ray-tube monitor daily quality-tested according to German regulations. The true caries status was determined from serial sectioning and microscopic evaluation. 16 experienced observers evaluated the radiographs on a five-point confidence scale on all prints plus the viewing monitor with respect to the visibility of a carious lesion. A non-parametric Receiver-Operating Characteristics (ROC-) analysis was performed explicitly designed for the evaluation of readings stemming from identical samples but different modality. Significant differences are expressed by a critical ratio z exceeding ±2. Diagnostic accuracy was determined by the area (Az) underneath the ROC-curves.
RESULTS: Average Az-values ranged between 0.62 (S520 and R2400) and 0.64 (monitor, iP4500), with no significant difference between modalities (P=0.172). Neither significant (range mean z: -0.40 (S520) and -0.11 (iP4500)) nor clinically relevant differences were found between printers and viewing monitor.
CONCLUSIONS: Our results for a challenging task in dental radiography indicate that calibrated, off-the-shelf ink-jet printers are able to reproduce (dental) radiographs at quality levels sufficient for radiographic diagnosis in a typical dental working environment.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20185261     DOI: 10.1016/j.ejrad.2010.01.015

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  2 in total

1.  Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography.

Authors:  K Kamburoglu; E Kolsuz; S Murat; S Yüksel; T Ozen
Journal:  Dentomaxillofac Radiol       Date:  2012-09       Impact factor: 2.419

2.  Assessing the Accuracy of Caries Diagnosis in Bitewing Radiographs Using Different Reproduction Media.

Authors:  Sadaf Adibi; Anita Amrollahi; Ali Dehghani Nazhvani; Najmeh Movahhedian
Journal:  J Dent (Shiraz)       Date:  2018-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.