Literature DB >> 20185109

Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patients.

Michael O Sweeney1, Lou Sherfesee, Paul J DeGroot, Mark S Wathen, Bruce L Wilkoff.   

Abstract

BACKGROUND: Implantable cardioverter-defibrillator (ICD) shocks have been associated with an increased risk of death. It is unknown whether this is due to the ventricular arrhythmia (VA) or shocks and whether antitachycardia pacing (ATP) termination can reduce this risk.
OBJECTIVE: The purpose of this study was to determine whether mortality in ICD patients is influenced by the type of therapy (shocks of ATP) delivered.
METHODS: Cox models evaluated effects of baseline characteristics, ventricular tachycardia (VT; <188 bpm), fast VT (FVT; 188-250 bpm), ventricular fibrillation (VF; >250 bpm), and therapy type (shocks or ATP) on mortality among 2135 patients in four trials of ATP to reduce shocks.
RESULTS: Over 10.8 +/- 3.3 months, 24.3% patients received appropriate shocks (50.6%) or ATP only (49.4%), and 6.6% died. Mortality predictors were age (hazard ratio 1.07, 95% confidence interval 1.04-1.08, P <.0001), New York Heart Association class III/IV (3.50 [2.27-5.41]; P <.0001), coronary disease (3.08 [1.31-7.25]; P = .01), and cumulative VA (VT + FVT + VF) episodes shocked (1.20 [1.13, 1.29]; P <.0001). Beta-blockers (0.65, 0.46-0.92; P <.0001) and remote myocardial infarction (0.53, [0.38-0.76] P = .0004) predicted reduced risk. Since 92% of VT and all VF received a single therapy type (ATP and shocks, respectively), the effect of therapy on episode risk could not be established. For FVT (32% shocked, 68% ATP), episode and therapy effects could be uncoupled; ATP-terminated FVT did not increase episode mortality risk, whereas shocked FVT increased risk by 32%. Survival rates were highest among patients with no VA (93.8%) of ATP-only (94.7%) and lowest for shocked patients (88.4%). Monthly episode rates were 80% higher among shocked versus ATP-only patients.
CONCLUSIONS: Shocked VA episodes are associated with increased mortality risk. Shocked patients have substantially higher VA episode burden and poorer survival compared with ATP-only-treated patients. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 20185109     DOI: 10.1016/j.hrthm.2009.11.027

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  52 in total

Review 1.  The emerging role of cardiac resynchronization therapy in milder heart failure: are we implanting too late for response?

Authors:  Jason Bradfield; Noel G Boyle; Ravi Mandapati; Kalyanam Shivkumar
Journal:  Curr Heart Fail Rep       Date:  2012-03

2.  [Is intraoperative ICD-testing still necessary?].

Authors:  C Mewis; H-R Neuberger; A Buob
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-06

3.  Modifying Ventricular Fibrillation by Targeted Rotor Substrate Ablation: Proof-of-Concept from Experimental Studies to Clinical VF.

Authors:  David E Krummen; Justin Hayase; Stephen P Vampola; Gordon Ho; Amir A Schricker; Gautam G Lalani; Tina Baykaner; Taylor M Coe; Paul Clopton; Wouter-Jan Rappel; Jeffrey H Omens; Sanjiv M Narayan
Journal:  J Cardiovasc Electrophysiol       Date:  2015-09-06

4.  Reduction of inappropriate ICD therapies in patients with primary prevention of sudden cardiac death: DECREASE study.

Authors:  Jörg Otto Schwab; Hendrik Bonnemeier; Thomas Kleemann; Johannes Brachmann; Sven Fischer; Frank Birkenhauer; Frank Eberhardt
Journal:  Clin Res Cardiol       Date:  2015-05-23       Impact factor: 5.460

Review 5.  The Potential Application of Heavy Ion Beams in the Treatment of Arrhythmia: The Role of Radiation-Induced Modulation of Connexin43 and the Sympathetic Nervous System.

Authors:  Mari Amino; Koichiro Yoshioka; Tadashi Kamada; Yoshiya Furusawa
Journal:  Int J Part Ther       Date:  2018-09-21

6.  The Significance of Shocks in Implantable Cardioverter Defibrillator Recipients.

Authors:  Anthony Li; Amit Kaura; Nicholas Sunderland; Paramdeep S Dhillon; Paul A Scott
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-08

Review 7.  How to improve outcomes: should we put more emphasis on programming and medical care and less on patient selection?

Authors:  Laszlo Buga
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

Review 8.  ICD programming to reduce shocks and improve outcomes.

Authors:  Valentina Kutyifa; Wojciech Zareba; Arthur J Moss
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

Review 9.  Ventricular Tachycardia with ICD Shocks: When to Medicate and When to Ablate.

Authors:  Amir AbdelWahab; John Sapp
Journal:  Curr Cardiol Rep       Date:  2017-09-13       Impact factor: 2.931

10.  Long-Term Follow-Up of Catheter Ablation of Ventricular Arrhythmias: Experiences from a Tertiary Referral Center in Taiwan.

Authors:  Fa-Po Chung; Yenn-Jiang Lin; Shih-Lin Chang; Li-Wei Lo; Yu-Feng Hu; Yun-Yu Chen; Chuen-Wang Chiou; Shih-Ann Chen
Journal:  Acta Cardiol Sin       Date:  2015-01       Impact factor: 2.672

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.