| Literature DB >> 20183060 |
James J Keenan1, Helen Vega, Robert I Krieger.
Abstract
The magnitude and distribution of cypermethrin from total release, over-the-counter foggers was studied in a test room and in residences to facilitate evaluation of regulatory exposure algorithms and new human exposure assessments based upon urine biomonitoring. Surface residue (SR) was evenly distributed in a small test room (3.6 mciro g cypermethrin/cm(2)) where thorough mixing of the aerosol occurred. In a residence SR was significantly affected by room size and distance from the fogger. Air levels in the residence were as high as 30 mciro g cypermethrin/cm(3) after 4.5 h. The availability of surface residues was measured with an automated surface cotton cloth wipe and ethyl acetate extraction. Only 5% of the SR was available from nylon carpet. Tile, wood and linoleum resulted in 30, 10, and 10% of SR being available, respectively. These data are used to estimate cypermethrin exposure of children and adults for comparison with existing regulatory reference dosages and exposure assessments based upon biomonitoring.Entities:
Mesh:
Substances:
Year: 2009 PMID: 20183060 DOI: 10.1080/03601230902997733
Source DB: PubMed Journal: J Environ Sci Health B ISSN: 0360-1234 Impact factor: 1.990