Literature DB >> 20182348

Discard tubes are not necessary when drawing samples for specialized coagulation testing.

Kristi J Smock1, Ronda A Crist, Sarah J Hansen, George M Rodgers, Christopher M Lehman.   

Abstract

Discard tubes have traditionally been obtained when drawing samples for coagulation testing to avoid potential tissue factor activation of coagulation in the first tube that may lead to inaccurate results. Although discard tubes are no longer required for prothrombin time and partial thromboplastin time, the practice is still recommended for other coagulation studies due to lack of sufficient evidence that discard tubes are not needed. The objective of the present study was to determine whether the first citrate tube drawn can be used for special coagulation testing. We performed testing for fibrinogen, D-dimer, factors VIII, IX, XI, proteins C and S, and antithrombin on 30 healthy individuals and factors II, VII, IX, X, and proteins C and S on a second group of 30 healthy individuals and 30 individuals receiving warfarin. Testing was performed on two consecutive samples to evaluate the level of agreement between the two tubes. Paired t-testing showed no statistically significant differences between tube 1 and tube 2 for any of the tests performed. Most data pairs (tube 1, tube 2) agreed within 10% difference or less, and no positive or negative biases were observed. To our knowledge, this study is the first to evaluate the need for discard tubes in a variety of coagulation tests using both normal and abnormal samples. Our data suggest that discard tubes are not necessary when drawing samples for specialized coagulation testing.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20182348     DOI: 10.1097/MBC.0b013e3283380d12

Source DB:  PubMed          Journal:  Blood Coagul Fibrinolysis        ISSN: 0957-5235            Impact factor:   1.276


  3 in total

1.  Routine coagulation testing: do we need a discard tube?

Authors:  Markas Masih; Naveen Kakkar
Journal:  Indian J Hematol Blood Transfus       Date:  2013-07-09       Impact factor: 0.900

Review 2.  Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.

Authors:  A Magnette; M Chatelain; B Chatelain; H Ten Cate; F Mullier
Journal:  Thromb J       Date:  2016-12-12

Review 3.  Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling.

Authors:  Nora Nikolac; Vesna Supak-Smolcić; Ana-Maria Simundić; Ivana Celap
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.