Literature DB >> 20182000

Home monitoring of within-breath respiratory mechanics by a simple and automatic forced oscillation technique device.

Raffaele L Dellacà1, Alessandro Gobbi, Miriam Pastena, Antonio Pedotti, Bartolomè Celli.   

Abstract

Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring of airway obstruction. We developed a FOT device for home monitoring of Zrs which transmits the data through the Internet. Its accuracy, stability and reliability were evaluated in a pilot study measuring the Zrs in the unsupervised self-measurements of five healthy subjects. Finally, to explore the applicability of the concept, 36 consecutive daily home measurements were recorded from one healthy subject and one chronic obstructive pulmonary disease (COPD) patient. The accuracy of the device fulfilled FOT guidelines, and the reliability test showed a mean discrepancy of resistance of 0.10 +/- 0.01 cmH(2)O s L(-1). The data from the healthy subjects demonstrated high repeatability in assessing Zrs. The measurements on the healthy subjects and the patient with COPD suggest the feasibility of unsupervised FOT measurements. The healthy subjects showed minimal daily variations in Zrs, whereas the patient with COPD had large differences in mean values and important fluctuations over day-to-day measurements. The results of the pilot study demonstrate that unsupervised home monitoring of Zrs using the FOT yields accurate and reproducible data. It could provide new insights into the dynamics of airway obstruction and improve the understanding and management of obstructive diseases.

Entities:  

Mesh:

Year:  2010        PMID: 20182000     DOI: 10.1088/0967-3334/31/4/N01

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Monitoring the temporal changes of respiratory resistance: a novel test for the management of asthma.

Authors:  Carlo Gulotta; Béla Suki; Vito Brusasco; Riccardo Pellegrino; Alessandro Gobbi; Antonio Pedotti; Raffaele L Dellacà
Journal:  Am J Respir Crit Care Med       Date:  2012-06-15       Impact factor: 21.405

Review 2.  Oscillation mechanics of the respiratory system: applications to lung disease.

Authors:  David W Kaczka; Raffaele L Dellacá
Journal:  Crit Rev Biomed Eng       Date:  2011

3.  Total inspiratory and expiratory impedance in patients with severe chronic obstructive pulmonary disease.

Authors:  Karla Kristine Dames Silva; Agnaldo José Lopes; José Manoel Jansen; Pedro Lopes de Melo
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

4.  Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects.

Authors:  Joanna C Watts; Claude S Farah; Leigh M Seccombe; Blake M Handley; Robin E Schoeffel; Amy Bertolin; Jessica Dame Carroll; Gregory G King; Cindy Thamrin
Journal:  ERJ Open Res       Date:  2016-04-13

Review 5.  Brazilian studies on pulmonary function in COPD patients: what are the gaps?

Authors:  Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2016-07-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.