Literature DB >> 20181771

Trapeziometacarpal joint implants can be evaluated by roentgen stereophotogrammetric analysis.

T B Hansen1, K Larsen, L Bjergelund, M Stilling.   

Abstract

Both marker-based roentgen stereophotogrammetric analysis (RSA) and model-based RSA have been helpful evaluation tools in hip and knee arthroplasty. The purpose of this study was to test both model-based and marker-based RSA in the evaluation of total joint prostheses of the trapeziometacarpal joint. In a phantom study, the precision of marker-based RSA was tested with a cemented polyethylene cup and compared with the precision of model-based RSA in an uncemented Elektra screw cup. The precision of model-based RSA of the metacarpal stem was tested using an uncemented Elektra metacarpal stem. In a clinical study 11 patients had double stereo radiographs followed by RSA analysis. The precision of translation in both marker-based and model-based RSA was sufficient for clinical use, but rotation cannot be estimated with sufficient precision.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20181771     DOI: 10.1177/1753193409355627

Source DB:  PubMed          Journal:  J Hand Surg Eur Vol        ISSN: 0266-7681


  6 in total

1.  Feasibility of model-based Roentgen Stereophotogrammetric Analysis to evaluate early migration of the trapeziometacarpal joint prosthesis.

Authors:  E M Ooms; B ten Brinke; N M C Mathijssen; I F Blom; R L M Deijkers; G A Kraan
Journal:  BMC Musculoskelet Disord       Date:  2015-10-14       Impact factor: 2.362

2.  Outcome of uncemented trapeziometacarpal prosthesis for treatment of thumb carpometacarpal joint arthritis.

Authors:  Manish Chug; Nicole Williams; David Benn; Stephen Brindley
Journal:  Indian J Orthop       Date:  2014-07       Impact factor: 1.251

Review 3.  The accuracy and precision of radiostereometric analysis in upper limb arthroplasty.

Authors:  Bart Ten Brinke; Annechien Beumer; Koen L M Koenraadt; Denise Eygendaal; Gerald A Kraan; Nina M C Mathijssen
Journal:  Acta Orthop       Date:  2017-03-02       Impact factor: 3.717

4.  Mechanical Stability of the Prodisc-C Vivo Cervical Disc Arthroplasty: A Preliminary, Observational Study Using Radiostereometric Analysis.

Authors:  Miranda L van Hooff; Petra J C Heesterbeek; Maarten Spruit
Journal:  Global Spine J       Date:  2019-05-23

5.  A radiostereometric and clinical long-term follow-up study of the surface replacement trapeziometacarpal joint prosthesis.

Authors:  Bart Ten Brinke; Nina M C Mathijssen; Ian F Blom; Lennard A Koster; Gerald A Kraan
Journal:  BMC Musculoskelet Disord       Date:  2021-02-05       Impact factor: 2.362

6.  Equally good fixation of cemented and uncemented cups in total trapeziometacarpal joint prostheses. A randomized clinical RSA study with 2-year follow-up.

Authors:  Torben Baek Hansen; Maiken Stilling
Journal:  Acta Orthop       Date:  2013-01-23       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.