Abstract

Detailed imaging of complex blood flow may improve early diagnosis of cardiovascular disease. In clinical practice, non-invasive flow imaging has been limited to one-dimensional Doppler techniques. Searching for multi-dimensional estimators, research has given attention to speckle tracking (ST) and vector Doppler (VD). However, these techniques have yet to be validated for complex flow patterns as may arise in diseased arteries. In this work, the properties of ST and crossed-beam VD are compared with a ground truth for clinically relevant flow using an ultrasonic simulation environment coupled with the output from computational fluid dynamics (CFD). The statistical properties (n = 80) of ST and VD were first evaluated for stationary flow in a tube for varying vessel positions and angles, and for varying noise levels. The parameter study demonstrated VD to be a more robust axial velocity estimator, and similar results were obtained overall for the lateral velocity component. As an example, the relative standard deviation was 15% and 8% for ST compared with 3% and 10% for VD, for the axial and lateral velocity component, respectively. Further, performance was evaluated for pulsatile flow conditions in a stenosed carotid bifurcation model. A linear regression analysis showed that both methods overall had a good agreement to the CFD reference, however VD suffered from more spurious artifacts and was severely hampered by aliasing in parts of the cardiac cycle. ST was less accurate in estimating the axial component, but prevailed in estimating velocities well beyond the Nyquist range. Based on our simulations, both methods may be used to image complex flow behavior in the carotid bifurcation, however, considering also the scanning limitations of VD, ST may provide a more consistent and practical approach. Future work will entail in vitro and in vivo validation of these results.

Entities:  

Mesh:

Year:  2010        PMID: 20178899     DOI: 10.1109/TUFFC.2010.1413

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  4 in total

1.  3-D ultrafast Doppler imaging applied to the noninvasive mapping of blood vessels in vivo.

Authors:  Jean Provost; Clement Papadacci; Charlie Demene; Jean-Luc Gennisson; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-08       Impact factor: 2.725

2.  Pulse Wave Imaging Coupled With Vector Flow Mapping: A Phantom, Simulation, and In Vivo Study.

Authors:  Grigorios Marios Karageorgos; Iason-Zacharias Apostolakis; Pierre Nauleau; Vittorio Gatti; Rachel Weber; Paul Kemper; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-06-29       Impact factor: 3.267

3.  Advanced echocardiography in adult zebrafish reveals delayed recovery of heart function after myocardial cryoinjury.

Authors:  Selina J Hein; Lorenz H Lehmann; Mandy Kossack; Lonny Juergensen; Dieter Fuchs; Hugo A Katus; David Hassel
Journal:  PLoS One       Date:  2015-04-08       Impact factor: 3.240

Review 4.  Review of photoacoustic flow imaging: its current state and its promises.

Authors:  P J van den Berg; K Daoudi; W Steenbergen
Journal:  Photoacoustics       Date:  2015-08-13