Literature DB >> 20178370

Fabrication of two-layered channel system with embedded electrodes to measure resistance across epithelial and endothelial barriers.

Nicholas J Douville1, Yi-Chung Tung, Ran Li, Jack D Wang, Mohamed E H El-Sayed, Shuichi Takayama.   

Abstract

This manuscript describes a straightforward fabrication process for embedding Ag/AgCl electrodes within a two-layer poly(dimethylsiloxane) (PDMS) microfluidic chip where an upper and a lower channel are separated by a semiporous membrane. This system allows for the reliable real-time measurement of transendothelial and transepithelial electrical resistance (TEER), an accepted quantification of cell monolayer integrity, across cells cultured on membranes inside the microchannels using impedance spectroscopy. The technique eliminates the need for costly or specialized microelectrode fabrication, enabling commercially available wire electrodes to easily be incorporated into PDMS microsystems for measuring TEER under microfluidic environments. The capability of measuring impedance across a confluent cell monolayer is confirmed using (i) brain-derived endothelial cells (bEND.3), (ii) Madin Darby Canine Kidney Cells (MDCK-2), and mouse myoblast (C2C12) (all from ATCC, Manassas, VA). TEER values as a function of cell type and cell culture time were measured and both agree with previously published values from macroscale culture techniques. This system opens new opportunities for conveniently resolving both transendothelial and transepithelial electrical resistance to monitor cell function in real-time in microfluidic cell cultures.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20178370      PMCID: PMC2839931          DOI: 10.1021/ac9029345

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  36 in total

1.  Endothelial barrier function under laminar fluid shear stress.

Authors:  J Seebach; P Dieterich; F Luo; H Schillers; D Vestweber; H Oberleithner; H J Galla; H J Schnittler
Journal:  Lab Invest       Date:  2000-12       Impact factor: 5.662

2.  A microfluidic device for measuring cellular membrane potential.

Authors:  J Farinas; A W Chow; H G Wada
Journal:  Anal Biochem       Date:  2001-08-15       Impact factor: 3.365

3.  High-throughput and high-resolution flow cytometry in molded microfluidic devices.

Authors:  Claire Simonnet; Alex Groisman
Journal:  Anal Chem       Date:  2006-08-15       Impact factor: 6.986

4.  Impedance analysis of epithelial and endothelial cell monolayers cultured on gold surfaces.

Authors:  J Wegener; M Sieber; H J Galla
Journal:  J Biochem Biophys Methods       Date:  1996-07-10

5.  Electrical resistance measurements on cerebral capillary endothelial cells--a new technique to study small surface areas.

Authors:  M Erben; S Decker; H Franke; H J Galla
Journal:  J Biochem Biophys Methods       Date:  1995-11

6.  Identification of two strains of MDCK cells which resemble separate nephron tubule segments.

Authors:  J C Richardson; V Scalera; N L Simmons
Journal:  Biochim Biophys Acta       Date:  1981-02-18

7.  Electrical properties of the rabbit urinary bladder assessed using gramicidin D.

Authors:  S A Lewis; N K Wills
Journal:  J Membr Biol       Date:  1982       Impact factor: 1.843

8.  AVP reduces transepithelial resistance across IMCD cell monolayers.

Authors:  D R Mishler; J A Kraut; G T Nagami
Journal:  Am J Physiol       Date:  1990-06

9.  Electrical method for detection of endothelial cell shape change in real time: assessment of endothelial barrier function.

Authors:  C Tiruppathi; A B Malik; P J Del Vecchio; C R Keese; I Giaever
Journal:  Proc Natl Acad Sci U S A       Date:  1992-09-01       Impact factor: 11.205

10.  Direct detection of renal function markers using microchip CE with pulsed electrochemical detection.

Authors:  Carlos D Garcia; Charles S Henry
Journal:  Analyst       Date:  2004-05-12       Impact factor: 4.616

View more
  40 in total

1.  An optically transparent membrane supports shear stress studies in a three-dimensional microfluidic neurovascular unit model.

Authors:  Katelyn L Sellgren; Brian T Hawkins; Sonia Grego
Journal:  Biomicrofluidics       Date:  2015-11-12       Impact factor: 2.800

2.  Effect of rhamnolipids on permeability across Caco-2 cell monolayers.

Authors:  Charity J Wallace; Scott H Medina; Mohamed E H ElSayed
Journal:  Pharm Res       Date:  2013-09-25       Impact factor: 4.200

Review 3.  Using physiologically-based pharmacokinetic-guided "body-on-a-chip" systems to predict mammalian response to drug and chemical exposure.

Authors:  Jong Hwan Sung; Balaji Srinivasan; Mandy Brigitte Esch; William T McLamb; Catia Bernabini; Michael L Shuler; James J Hickman
Journal:  Exp Biol Med (Maywood)       Date:  2014-06-20

4.  Finite element modeling to analyze TEER values across silicon nanomembranes.

Authors:  Tejas S Khire; Barrett J Nehilla; Jirachai Getpreecharsawas; Maria E Gracheva; Richard E Waugh; James L McGrath
Journal:  Biomed Microdevices       Date:  2018-01-05       Impact factor: 2.838

5.  Microfluidic organs-on-chips.

Authors:  Sangeeta N Bhatia; Donald E Ingber
Journal:  Nat Biotechnol       Date:  2014-08       Impact factor: 54.908

Review 6.  TEER measurement techniques for in vitro barrier model systems.

Authors:  Balaji Srinivasan; Aditya Reddy Kolli; Mandy Brigitte Esch; Hasan Erbil Abaci; Michael L Shuler; James J Hickman
Journal:  J Lab Autom       Date:  2015-01-13

7.  An isogenic hiPSC-derived BBB-on-a-chip.

Authors:  Pedram Motallebnejad; Andrew Thomas; Sarah L Swisher; Samira M Azarin
Journal:  Biomicrofluidics       Date:  2019-11-22       Impact factor: 2.800

Review 8.  Microfabricated mammalian organ systems and their integration into models of whole animals and humans.

Authors:  Jong H Sung; Mandy B Esch; Jean-Matthieu Prot; Christopher J Long; Alec Smith; James J Hickman; Michael L Shuler
Journal:  Lab Chip       Date:  2013-04-07       Impact factor: 6.799

9.  In-Line Analysis of Organ-on-Chip Systems with Sensors: Integration, Fabrication, Challenges, and Potential.

Authors:  Stefanie Fuchs; Sofia Johansson; Anders Ø Tjell; Gabriel Werr; Torsten Mayr; Maria Tenje
Journal:  ACS Biomater Sci Eng       Date:  2021-06-16

Review 10.  Microchip-based electrochemical detection for monitoring cellular systems.

Authors:  Alicia S Johnson; Asmira Selimovic; R Scott Martin
Journal:  Anal Bioanal Chem       Date:  2013-01-23       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.