Literature DB >> 20177101

Partially resected gliomas: diagnostic performance of fluid-attenuated inversion recovery MR imaging for detection of progression.

Marianne Winterstein1, Marc W Münter, Iris Burkholder, Marco Essig, Hans-Ulrich Kauczor, Marc-André Weber.   

Abstract

PURPOSE: To assess whether signal intensity (SI) different from that of cerebrospinal fluid (CSF) within the resection cavity during follow-up helps predict tumor progression in partially resected gliomas.
MATERIALS AND METHODS: This retrospective study had local institutional review board approval, with waiver of informed consent. Seventy-five patients with partially resected and irradiated gliomas were evaluated. SI within the resection cavity on fluid-attenuated inversion recovery (FLAIR) magnetic resonance (MR) images was qualitatively and quantitatively assessed during follow-up. Qualitative analysis comprised visual comparison of SI in the resection cavity with SI of normal CSF by two readers. SI of the cavity was quantitatively assessed with region-of-interest (ROI) analysis normalized to background noise, contralateral healthy white matter, and CSF. Normalized SI during follow-up was compared with SI immediately after resection. Tumor progression was defined as increase in longest glioma diameter of at least 20% (Response Evaluation Criteria in Solid Tumors). Sensitivity and specificity of elevated SI in resection cavities for predicting or indicating tumor progression were calculated. Wilcoxon rank-sum test, Hodges-Lehman estimates, Kaplan-Meier curves, and linear mixed-effect models for repeated-measures data were used for quantitative SI measurements.
RESULTS: Tumor progression at MR was seen in 44 patients (59%), and median progression-free survival was 4.1 years. Qualitative analysis showed that 25 of 44 patients with progression (57%) had SI increase in the resection cavity on FLAIR images. In 10 patients with progression (23%), SI increase was seen a mean of 5 months +/- 3 (standard deviation) before tumor size progression. In 15 patients with progression (34%), SI increase and tumor size progression were detected on the same MR study. In 19 patients with progressing glioma (43%), no SI increase was observed qualitatively. Among 31 patients without progression during follow-up (41%), no SI increase could be observed. Quantitative analysis showed no significant differences in ROI ratios at baseline (after surgery) between progressing and nonprogressing tumors, whereas significant differences in change of ROI ratios at the last measurement could be detected. Overall, SI increase on FLAIR images had specificity of 100% (95% confidence interval [CI]: 91%, 100%) and sensitivity of 57% (95% CI: 42%, 71%) for glioma progression.
CONCLUSION: In partially resected gliomas, encapsulation of resection cavity, presumably by tumor cells, manifests as SI increase on FLAIR images and indicates tumor progression with very high specificity. (c) RSNA, 2010.

Entities:  

Mesh:

Year:  2010        PMID: 20177101     DOI: 10.1148/radiol09090893

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Non-rigid registration with missing correspondences in preoperative and postresection brain images.

Authors:  Nicha Chitphakdithai; James S Duncan
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

2.  Early imaging marker of progressing glioblastoma: a window of opportunity.

Authors:  Na Tosha N Gatson; Shane P Bross; Yazmin Odia; Gino J Mongelluzzo; Yirui Hu; Laura Lockard; Jesse J Manikowski; Anand Mahadevan; Syed A J Kazmi; Michel Lacroix; Andrew R Conger; Joseph Vadakara; Lakshmi Nayak; T Linda Chi; Minesh P Mehta; Vinay K Puduvalli
Journal:  J Neurooncol       Date:  2020-06-29       Impact factor: 4.130

3.  Increased signal intensity within glioblastoma resection cavities on fluid-attenuated inversion recovery imaging to detect early progressive disease in patients receiving radiotherapy with concomitant temozolomide therapy.

Authors:  Luke A Perry; Panagiotis Korfiatis; Jay P Agrawal; Bradley J Erickson
Journal:  Neuroradiology       Date:  2017-11-04       Impact factor: 2.804

4.  Increasing FLAIR signal intensity in the postoperative cavity predicts progression in gross-total resected high-grade gliomas.

Authors:  Guan-Min Quan; Yong-Li Zheng; Tao Yuan; Jian-Ming Lei
Journal:  J Neurooncol       Date:  2018-03-21       Impact factor: 4.130

5.  Post-treatment imaging of high-grade gliomas.

Authors:  Darshana Sanghvi
Journal:  Indian J Radiol Imaging       Date:  2015 Apr-Jun

6.  T2/FLAIR Abnormity Could be the Sign of Glioblastoma Dissemination.

Authors:  Mingxiao Li; Wei Huang; Hongyan Chen; Haihui Jiang; Chuanwei Yang; Shaoping Shen; Yong Cui; Gehong Dong; Xiaohui Ren; Song Lin
Journal:  Front Neurol       Date:  2022-02-02       Impact factor: 4.003

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.