Literature DB >> 20175683

Use of central venous catheter and peripheral venous catheter as risk factors for nosocomial bloodstream infection in very-low-birth-weight infants.

Christine Geffers1, Anne Gastmeier, Frank Schwab, Katrin Groneberg, Henning Rüden, Petra Gastmeier.   

Abstract

OBJECTIVE: To describe the relationship between the use of central and peripheral venous catheters and the risk of nosocomial, primary, laboratory-confirmed bloodstream infection (BSI) for neonates with a birth weight less than 1,500 g (very-low-birth-weight [VLBW] infants).
METHODS: Cox proportional hazard regression analysis with time-dependent variable was used to determine the risk factors for the occurrence of BSI in a cohort of VLBW infants. We analyzed previously collected surveillance data from the German national nosocomial surveillance system for VLBW infants. All VLBW infants in 22 participating neonatal departments who had a complete daily record of patient information were included.
RESULTS: Of 2,126 VLBW infants, 261 (12.3%) developed a BSI. The incidence density for BSI was 3.3 per 1,000 patient-days. The multivariate analysis identified the following significant independent risk factors for BSI: lower birth weight (hazard ratio [HR], 1.1-2.2), vaginal delivery (HR, 1.5), central venous catheter use (HR, 6.2) or peripheral venous catheter use (HR, 6.0) within 2 days before developing BSI, and the individual departments (HR, 0.0-4.6).
CONCLUSIONS: After adjusting for other risk factors, use of peripheral venous catheter and use of central venous catheter were significantly related to occurrence of BSI in VLBW infants.

Entities:  

Mesh:

Year:  2010        PMID: 20175683     DOI: 10.1086/651303

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  6 in total

1.  Surface modification of a polyethylene film for anticoagulant and anti-microbial catheter.

Authors:  Yingying Zheng; Jianjun Miao; Fuming Zhang; Chao Cai; Amanda Koh; Trevor J Simmons; Shaker A Mousa; Robert J Linhardt
Journal:  React Funct Polym       Date:  2016-03-01       Impact factor: 3.975

2.  Healthcare-associated Infections in Very Low Birth-weight Infants in a South African Neonatal Unit: Disease Burden, Associated Factors and Short-term Outcomes.

Authors:  Lizel Georgi Lloyd; Adrie Bekker; Mirjam M Van Weissenbruch; Angela Dramowski
Journal:  Pediatr Infect Dis J       Date:  2022-08-09       Impact factor: 3.806

3.  Preventable contributors to the neonatal healthcare-associated infections: a uni-center analytical study from South India.

Authors:  Usha Rani; Leslie E Lewis; Kiran Chawla; Anup Naha
Journal:  F1000Res       Date:  2022-04-25

Review 4.  Percutaneous central venous catheters versus peripheral cannulae for delivery of parenteral nutrition in neonates.

Authors:  Sean Ainsworth; William McGuire
Journal:  Cochrane Database Syst Rev       Date:  2015-10-06

5.  The impact of staffing on central venous catheter-associated bloodstream infections in preterm neonates - results of nation-wide cohort study in Germany.

Authors:  Rasmus Leistner; Sarah Thürnagel; Frank Schwab; Brar Piening; Petra Gastmeier; Christine Geffers
Journal:  Antimicrob Resist Infect Control       Date:  2013-04-04       Impact factor: 4.887

6.  Improving patient safety during insertion of peripheral venous catheters: an observational intervention study.

Authors:  Günter Kampf; Gesche Reise; Claudia James; Kirsten Gittelbauer; Jutta Gosch; Birgit Alpers
Journal:  GMS Hyg Infect Control       Date:  2013-11-06
  6 in total