Literature DB >> 20175491

Smoothing of respiratory motion traces for motion-compensated radiotherapy.

Floris Ernst1, Alexander Schlaefer, Achim Schweikard.   

Abstract

PURPOSE: The CyberKnife system has been used successfully for several years to radiosurgically treat tumors without the need for stereotactic fixation or sedation of the patient. It has been shown that tumor motion in the lung, liver, and pancreas can be tracked with acceptable accuracy and repeatability. However, highly precise targeting for tumors in the lower abdomen, especially for tumors which exhibit strong motion, remains problematic. Reasons for this are manifold, like the slow tracking system operating at 26.5 Hz, and using the signal from the tracking camera "as is." Since the motion recorded with the camera is used to compensate for system latency by prediction and the predicted signal is subsequently used to infer the tumor position from a correlation model based on x-ray imaging of gold fiducials around the tumor, camera noise directly influences the targeting accuracy. The goal of this work is to establish the suitability of a new smoothing method for respiratory motion traces used in motion-compensated radiotherapy. The authors endeavor to show that better prediction--With a lower rms error of the predicted signal--and/or smoother prediction is possible using this method.
METHODS: The authors evaluated six commercially available tracking systems (NDI Aurora, PolarisClassic, Polaris Vicra, MicronTracker2 H40, FP5000, and accuTrack compact). The authors first tracked markers both stationary and while in motion to establish the systems' noise characteristics. Then the authors applied a smoothing method based on the a trous wavelet decomposition to reduce the devices' noise level. Additionally, the smoothed signal of the moving target and a motion trace from actual human respiratory motion were subjected to prediction using the MULIN and the nLMS2 algorithms.
RESULTS: The authors established that the noise distribution for a static target is Gaussian and that when the probe is moved such as to mimic human respiration, it remains Gaussian with the exception of the FP5000 and the Aurora systems. The authors also showed that the proposed smoothing method can indeed be used to filter noise. The signal's jitter dropped by as much as 95% depending on the tracking system employed. Subsequently, the 3D prediction error (rms) for a prediction horizon of 150 ms on a synthetic signal dropped by up to 37% when using a normalized LMS prediction algorithm (nLMS2) and hardly changed when using a MULIN algorithm. When smoothing a real signal obtained in our laboratory, the improvement of prediction was similar: Up to 30% for both the nLMS2 and the best MULIN algorithm. The authors also found a noticeable increase in smoothness of the predicted signal, the relative jitter dropped by up to 95% on the real signal, and on the simulated signal.
CONCLUSIONS: In conclusion, the authors can say that preprocessing of marker data is very useful in motion-compensated radiotherapy since the quality of prediction increases. This will result in better performance of the correlation model. As a side effect, since the prediction of a preprocessed signal is also less noisy, the authors expect less robot vibration resulting in better targeting accuracy and less strain on the robot gears.

Entities:  

Mesh:

Year:  2010        PMID: 20175491     DOI: 10.1118/1.3271684

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy.

Authors:  Nikolas Leßmann; Daniel Drömann; Alexander Schlaefer
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-26       Impact factor: 2.924

2.  Factors affecting the accuracy of respiratory tracking of the image-guided robotic radiosurgery system.

Authors:  Mitsuhiro Inoue; Kohei Okawa; Junichi Taguchi; Yoshifumi Hirota; Yohei Yanagiya; Chie Kikuchi; Michio Iwabuchi; Taro Murai; Hiromitsu Iwata; Hiroya Shiomi; Izumi Koike; Koshi Tatewaki; Seiji Ohta
Journal:  Jpn J Radiol       Date:  2019-07-31       Impact factor: 2.374

3.  Evaluation of contrast-enhanced ultrasonography for hepatocellular carcinoma prior to and following stereotactic body radiation therapy using the CyberKnife® system: A preliminary report.

Authors:  Kazue Shiozawa; Manabu Watanabe; Takashi Ikehara; Kojiro Kobayashi; Yuta Ochi; Yuta Suzuki; Kazuhiro Fuchinoue; Masataka Yoneda; Takeshi Kenmochi; Yusuke Okubo; Takayuki Mori; Hiroyuki Makino; Nobuhiro Tsukamoto; Yoshinori Igarashi; Yasukiyo Sumino
Journal:  Oncol Lett       Date:  2015-11-05       Impact factor: 2.967

4.  Development of system using beam's eye view images to measure respiratory motion tracking errors in image-guided robotic radiosurgery system.

Authors:  Mitsuhiro Inoue; Hiroya Shiomi; Hiromitsu Iwata; Junichi Taguchi; Kohei Okawa; Chie Kikuchi; Kosaku Inada; Michio Iwabuchi; Taro Murai; Izumi Koike; Koshi Tatewaki; Seiji Ohta; Tomio Inoue
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

5.  Correlated Skin Surface and Tumor Motion Modeling for Treatment Planning in Robotic Radiosurgery.

Authors:  Shumei Yu; Pengcheng Hou; Rongchuan Sun; Shaolong Kuang; Fengfeng Zhang; Mingchuan Zhou; Jing Guo; Lining Sun
Journal:  Front Neurorobot       Date:  2020-11-12       Impact factor: 2.650

6.  Comparative research on the efficacy of CyberKnife® and surgical excision for Stage I hepatocellular carcinoma.

Authors:  Zhiyong Yuan; Lijun Tian; Ping Wang; Yongchun Song; Yang Dong; Hongqing Zhuang
Journal:  Onco Targets Ther       Date:  2013-10-29       Impact factor: 4.147

  6 in total